Evidence map›Paper›PMID 38903014›Full record

ArticleJournal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale

Pull-Out Strength of Orthodontic Miniscrews in the Temporal Bone.

Christian Menke, Marcel Kluge, Bastian Welke, Thomas Lenarz, Omid Majdani, Thomas S Rau

Abstract read
In one paragraph

Article in Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Christian MenkeDepartment of Pediatric Kidney, Liver and Metabolic Diseases, Hannover Medical School, Hannover, Germany.ORCID 0000-0002-8885-1154
Marcel KlugeOtojig GmbH, Hannover, Germany.
Bastian WelkeLaboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Hannover, Germany.
Thomas LenarzDepartment of Otolaryngology and Cluster of Excellence, "Hearing4all," Hannover Medical School, Hannover, Germany.
Omid MajdaniDepartment of Otolaryngology, Medizincampus Wolfsburg der Universitätsmedizin Göttingen, Wolfsburg, Germany.
Thomas S RauDepartment of Otolaryngology and Cluster of Excellence, "Hearing4all," Hannover Medical School, Hannover, Germany.ORCID 0000-0002-7223-3618

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMinimally invasive cochlear implant surgery by using a microstereotactic frame demands solid connection to the bone. We aimed to determine the stability of commercially available orthodontic miniscrews to evaluate their feasibility for frame's fixation. In addition, which substitute material most closely resembles the mechanical properties of the human temporal bone was evaluated.

methodsPull-out tests were carried out with five different types of orthodontic miniscrews in human temporal bone specimens. Furthermore, short fiber filled epoxy (SFFE), solid rigid polyurethane (SRPU50), bovine femur, and porcine iliac bone were evaluated as substitute materials. In total, 57 tests in human specimens and 180 tests in the substitute materials were performed.

resultsIn human temporal bone, average pull-out forces ranged from 220 N to 285 N between screws. Joint stiffness in human temporal bone ranged between 14 N/mm and 358 N/mm. Statistically significant differences between the tested screws were measured in terms of stiffness and elastic energy. One screw type failed insertion due to tip breakage. No significant differences occurred between screws in maximum pull-out force. The average pull-out values of SFFE were 14.1 N higher compared to human specimen.

conclusionOrthodontic miniscrews provided rigid fixation when partially inserted in human temporal bone, as evidenced by pull-out forces and joint stiffness. Average values exceeded requirements despite variations between screws. Differences in stiffness and elastic energy indicate screw-specific interface mechanics. With proper insertion, orthodontic miniscrews appear suitable for microstereotactic frame anchoring during minimally invasive cochlear implant surgery. However, testing under more complex loading is needed to better predict clinical performance. For further pull-out tests, the most suitable substitute material is SFFE.

Indexed as

Bone ScrewsTemporal BoneAnimalsCadaverCattleCochlear ImplantationHumansMaterials TestingMinimally Invasive Surgical ProceduresSwinebone substitute materialminimally invasive cochlear implant surgeryorthodontic miniscrewspull-out test