Is conventional magnetic resonance imaging superior to radiography in the functional integrity evaluation of anterior cruciate ligament in patients with knee osteoarthritis?

Zhenguo Yu, Hongqing Wang, Xiaoyu Wang, Xin Dong, Jie Dong, Qingchen Liang, Fenglong Sun

Abstract read
In one paragraph

Article in Arthroplasty (London, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhenguo YuDepartment of Orthopedics II, Beijing Rehabilitation Hospital, Capital Medical University, Xixiazhuang, Shijingshan District, Beijing, 100144, China.
Hongqing WangDepartment of Orthopedics II, Beijing Rehabilitation Hospital, Capital Medical University, Xixiazhuang, Shijingshan District, Beijing, 100144, China.
Xiaoyu WangDepartment of Dermatology, Peking University Third Hospital, No.49 North Garden Road, Haidian District, Beijing, 100191, China.
Xin DongDepartment of Orthopedics II, Beijing Rehabilitation Hospital, Capital Medical University, Xixiazhuang, Shijingshan District, Beijing, 100144, China.
Jie DongDepartment of Orthopedics II, Beijing Rehabilitation Hospital, Capital Medical University, Xixiazhuang, Shijingshan District, Beijing, 100144, China.
Qingchen LiangDepartment of Orthopedics II, Beijing Rehabilitation Hospital, Capital Medical University, Xixiazhuang, Shijingshan District, Beijing, 100144, China.
Fenglong SunDepartment of Orthopedics II, Beijing Rehabilitation Hospital, Capital Medical University, Xixiazhuang, Shijingshan District, Beijing, 100144, China. sunfenglong@ccmu.edu.cn.

Funding

Beijing Rehabilitation Hospital Research Fund 2021R-007
6 · The paper itself

Abstract

backgroundThe functional integrity of the anterior cruciate ligament (ACL) influences surgical decision-making in patients with knee osteoarthritis (KOA). This study aimed to compare the diagnostic value of radiography and magnetic resonance imaging (MRI) in determining the functional status of ACL.

methodsWe analyzed 306 knees retrospectively using preoperative hip-to-ankle anteroposterior standing (APS) radiographs, anteroposterior (AP) and lateral knee radiographs, AP valgus stress (VS) force radiographs, and standard orthogonal MRI. Based on the intraoperative visualization, the knees were grouped into ACL functionally-intact and ACL functionally-deficient (ACLD) groups. The diagnostic validity and reliability were calculated based on the radiograph parameters such as hip-knee-ankle angle (HKA), medial proximal tibial angle (MPTA), lateral distal femoral angle (LDFA), posterior tibial slope (PTS), sagittal tibiofemoral subluxation (STFS), coronal tibiofemoral subluxation (CTFS), joint line convergence angle (JLCA), the maximum wear point of the proximal tibia plateau (MWPPT%), and MRI parameters including ACL grades and MWPPT%.

resultsHKA, MPTA, PTS, STFS, JLCA, and CTFS on APS and AP radiographs, and MWPPT% on radiographs and MRI showed a significant diagnostic value (P < 0.05). There were no statistically significant differences in the single parameters from radiographs and MRI. After constructing the logistic regression models, MRI showed higher sensitivity, specificity, and accuracy, reaching 96.8%, 79.9%, and 83.3%, respectively (P < 0.001).

conclusionsIn patients with KOA, the diagnostic value of single radiographic or MRI parameter in assessing the functional integrity of the ACL are equivalent. However, by constructing predictive models, MRI could significantly improve diagnostic validity compared with radiography.

Indexed as

Anterior cruciate ligamentDiagnostic validityKnee osteoarthritisMagnetic resonance imagingRadiography