Evidence map›Paper›PMID 38902667›Full record

ArticleBMC ophthalmology2024

Long-term efficacy and safety of XEN-45 gel stent implantation in patients with normal-tension glaucoma.

Emil Nasyrov, Caroline J Gassel, David A Merle, Jonas Neubauer, Bogomil Voykov

Abstract read
In one paragraph

Article in BMC ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Emil NasyrovCentre for Ophthalmology, University Hospital Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany. emil.nasyrov@med.uni-tuebingen.de.
Caroline J GasselCentre for Ophthalmology, University Hospital Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
David A MerleCentre for Ophthalmology, University Hospital Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
Jonas NeubauerCentre for Ophthalmology, University Hospital Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.
Bogomil VoykovCentre for Ophthalmology, University Hospital Tuebingen, Elfriede-Aulhorn-Str. 7, 72076, Tuebingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMinimally invasive bleb surgery using the XEN-45 gel stent has not been established for the treatment of normal-tension glaucoma (NTG). The main objective of this study was to evaluate the long-term treatment efficacy and safety of XEN-45 in eyes with uncontrolled NTG.

methodsA retrospective analysis of patients with NTG who underwent XEN-45 gel stent implantation at university hospital Tuebingen between 2016 and 2021. The primary outcome measure was surgical success after three years defined as lowering of intraocular pressure (IOP) of ≥ 20%, with target IOP between 6 and 15 mmHg. Success was complete without and qualified irrespective of topical antiglaucoma medication use. The need for further glaucoma surgery, except for needling, was regarded as a failure. The secondary outcome measures included changes in mean IOP, number of antiglaucoma medications, and needling and complication rates.

resultsTwenty-eight eyes from 23 patients were included in the final analysis. Complete and qualified success rates were 56.5% and 75% after three years, respectively. Mean postoperative IOP ± standard deviation decreased significantly after three years from 19.3 ± 2.0 mmHg at baseline to 13.7 ± 4.2 mmHg (n = 22; p < 0.0001). The median number of antiglaucoma medications decreased from 2 (range 0-4) to 0 after three years (range 0-3; p < 0.0001). Sixteen eyes (57%) required a median of 1 (range 1-3) needling procedures. One eye required further glaucoma surgery. No sight-threatening complications were observed.

conclusionThe XEN-45 stent is effective and safe for the long-term treatment of NTG. However, needling was frequently required to improve outcomes.

Indexed as

Glaucoma Drainage ImplantsIntraocular PressureLow Tension GlaucomaStentsAgedAged, 80 and overFemaleFollow-Up StudiesHumansMaleMiddle AgedProsthesis DesignProsthesis ImplantationRetrospective StudiesTreatment OutcomeVisual AcuityFiltering surgeryGel stentMIBSMIGSMinimally invasive glaucoma surgeryNeedlingNormal-tension glaucoma

Identifiers

PMID38902667
PMCPMC11191175

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.