Evidence map›Paper›PMID 38902457›Full record

ArticleInternational ophthalmology2024

Total and simulated keratometry measurements using IOLMaster 700 and Pentacam AXL after small incision lenticule extraction.

Qian Liu, Wenli Yang, Dongjun Li, Ziyang Wang, Wei Chen, Changbin Zhai, Wenbin Wei

Abstract read
PubMed Publisher
In one paragraph

Article in International ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Qian LiuBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China.
Wenli YangBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China. yangwl_tr@163.com.
Dongjun LiBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China.
Ziyang WangBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China.
Wei ChenBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China.
Changbin ZhaiBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China.
Wenbin WeiBeijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCalculating the intraocular lens (IOL) in patients after corneal refractive surgery presents a challenge. Because an overestimation of corneal power in cases undergone this surgery leading to a subsequent under-correction of IOL power. However, recent advancements in technology have eliable measurement of total corneal power. The aim of this research was to assess the agreement in simulated keratometry (SimK) and total keratometry (TK) values between IOLMaster 700 and Pentacam AXL.

methodsThe study involved 99 patients (99 eyes) undergone small incision lenticule extraction (SMILE) surgery. Each patient underwent scans using IOL Master 700 and Pentacam AXL. The following parameters were recorded: SimK1, SimK2, Total K1 (TK1), and Total K2 (TK2) for IOLMaster 700; and SimK1, SimK2, True Net Power (TNP) K1, TNPK2, Total Corneal Refractive Power (TCRP) K1, and TCRP K2 for Pentacam AXL. Agreement between the two devices was evaluated using Bland-Altman plot, while paired t-test was utilized to compare any differences in the same parameter by both instruments.

resultsThe results revealed a strong correlation between the two devices.Noticeable comparability was identified for all SimK variables. However, there were noticeable differences in TK measurements as well as TK1-TNPK1, TK2-TNP K2, TK1-TCRP K1, and TK2-TCRP K2 parameters when comparing the two devices. The IOLMaster 700 consistently measured steeper values than the Pentacam AXL, with significant and clinically relevant differences of 1.34, 1.37, 0.87, and 0.95 diopters, respectively.

conclusionWhile there was a noticeable correlation between the IOLMaster 700 and Pentacam AXL in SimK measurements, a marked difference was noted in TK values. The two devices cannot be used interchangeably when quantifying TK values.

Indexed as

CorneaCorneal TopographyMyopiaRefraction, OcularAdultBiometryCorneal Surgery, LaserFemaleHumansLenses, IntraocularMaleMiddle AgedProspective StudiesReproducibility of ResultsVisual AcuityYoung AdultIOLMaster 700Pentacam AXLSimulated keratometrySMILETotal keratometry