Evidence map›Paper›PMID 38900457›Full record

ArticleJournal of synchrotron radiation2024

Asymmetric electrostatic dodecapole: compact bandpass filter with low aberrations for momentum microscopy.

O Tkach, S Chernov, S Babenkov, Y Lytvynenko, O Fedchenko, K Medjanik, D Vasilyev, A Gloskowskii, C Schlueter, H J Elmers and 1 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

O TkachInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.ORCID 0000-0003-3207-2490
S ChernovDeutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
S BabenkovInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
Y LytvynenkoInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
O FedchenkoInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.ORCID 0000-0002-6159-7934
K MedjanikInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
D VasilyevInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.ORCID 0000-0003-2870-3851
A GloskowskiiDeutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
C SchlueterDeutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
H J ElmersInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.
G SchönhenseInstitut für Physik, Johannes Gutenberg-Universität Mainz, 55099 Mainz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Imaging energy filters in photoelectron microscopes and momentum microscopes use spherical fields with deflection angles of 90°, 180° and even 2 × 180°. These instruments are optimized for high energy resolution, and exhibit image aberrations when operated in high transmission mode at medium energy resolution. Here, a new approach is presented for bandpass-filtered imaging in real or reciprocal space using an electrostatic dodecapole with an asymmetric electrode array. In addition to energy-dispersive beam deflection, this multipole allows aberration correction up to the third order. Here, its use is described as a bandpass prefilter in a time-of-flight momentum microscope at the hard X-ray beamline P22 of PETRA III. The entire instrument is housed in a straight vacuum tube because the deflection angle is only 4° and the beam displacement in the filter is only ∼8 mm. The multipole is framed by transfer lenses in the entrance and exit branches. Two sets of 16 different-sized entrance and exit apertures on piezomotor-driven mounts allow selection of the desired bandpass. For pass energies between 100 and 1400 eV and slit widths between 0.5 and 4 mm, the transmitted kinetic energy intervals are between 10 eV and a few hundred electronvolts (full width at half-maximum). The filter eliminates all higher or lower energy signals outside the selected bandpass, significantly improving the signal-to-background ratio in the time-of-flight analyzer.

Indexed as

bandpass prefiltersdodecapoleshard X-ray angle-resolved photoelectron spectroscopyHARPESmomentum microscopyphotoelectron diffraction

Identifiers

PMID38900457
PMCPMC11226149

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.