ArticleJournal of controlled release : official journal of the Controlled Release Society2024
Cavitation monitoring, treatment strategy, and acoustic simulations of focused ultrasound blood-brain barrier disruption in patients with glioblastoma.
Article in Journal of controlled release : official journal of the Controlled Release Society, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Focused ultrasound-mediated blood-brain barrier opening to enhance temozolomide delivery in glioblastoma: a systematic review of preclinical and early clinical evidence.Neurosurgical review · 2026Pooled it
- Efficacy and safety of low- and high-intensity focused ultrasound in glioblastoma: a systematic review of preclinical and clinical studies.British journal of cancer · 2026Pooled it
- Ultrasound-Induced Cavitation as Biological Constraint Focusing: A Phenomenological Bioengineering Model for Sonoporation, Sonodynamic Therapy, Drug Delivery, and Histotripsy.Bioengineering (Basel, Switzerland) · 2026Article
- Noninvasive Focal Gene Delivery into the Cerebellum of Non-Human Primates using Focused Ultrasound.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- Applications of transcranial focused ultrasound for primary brain tumors.Neuro-oncology advances · 2026Review
- Transient blood-brain barrier opening by focused ultrasound enhances ferumoxytol accumulation in glioblastoma.Materials today. Bio · 2026Article
- Experimental evaluation of an integrated focused ultrasound and electroencephalography approach for developing activation-informed neuroimaging.NeuroImage · 2026Article
- From Polyphenols to Prodrugs: Bridging the Blood-Brain Barrier with Nanomedicine and Neurotherapeutics.International journal of molecular sciences · 2026Review
- Data-Driven Feedback Identifies Focused Ultrasound Exposure Regimens for Improved Nanotheranostic Targeting of the Brain.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- Hysteresis in cavitation emissions during a ramped-then-deramped amplitude sonication: A theoretical and experimental investigation.Nonlinear dynamics · 2026Article
- Advanced Neuroimaging and Emerging Systemic Therapies in Glioblastoma: Current Evidence and Future Directions.Biomedicines · 2025Review
- Acoustic emissions dose and spatial control of blood-brain barrier opening with focused ultrasound.Device · 2025Article
- Review
- Simulation Study on the Dynamics of Cavitation Bubbles in Multi-Frequency Ultrasound.Journal of biomedical physics & engineering · 2025Article
- Microvascular heterogeneity exploration in core and invasive zones of orthotopic rat glioblastoma via ultrasound localization microscopy.European radiology experimental · 2025Article
- Identifying new therapeutics for focused ultrasound-enhanced drug delivery in the management of glioblastoma.Frontiers in oncology · 2025Review
- Ultrasound combined with microbubble enhanced renoprotective effects of NLRP3 inflammasome inhibitor MCC950 in CKD model.Frontiers in pharmacology · 2025Article
- Recent Advances in Renal Denervation Therapy and Novel Applications of High-Intensity Focused Ultrasound.Cardiovascular therapeutics · 2025Review
- Bi-modal confirmation of liposome delivery to the brain after focused ultrasound-induced blood-brain barrier opening.Heliyon · 2024Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeWe report our experience disrupting the blood-brain barrier (BBB) to improve drug delivery in glioblastoma patients receiving temozolomide chemotherapy. The goals of this retrospective analysis were to compare MRI-based measures of BBB disruption and vascular damage to the exposure levels, acoustic emissions data, and acoustic simulations. We also simulated the cavitation detectors.
methodsMonthly BBB disruption (BBBD) was performed using a 220 kHz hemispherical phased array focused ultrasound system (Exablate Neuro, InSightec) and Definity microbubbles (Lantheus) over 38 sessions in nine patients. Exposure levels were actively controlled via the cavitation dose obtained by monitoring subharmonic acoustic emissions. The acoustic field and sensitivity profile of the cavitation detection system were simulated. Exposure levels and cavitation metrics were compared to the level of BBBD evident in contrast-enhanced MRI and to hypointense regions in T2*-weighted MRI.
resultsOur treatment strategy evolved from using a relatively high cavitation dose goal to a lower goal and longer sonication duration and ultimately resulted in BBBD across the treatment volume with minimal petechiae. Subsonication-level feedback control of the exposure using acoustic emissions also improved consistency. Simulations of the acoustic field suggest that reflections and standing waves appear when the focus is placed near the skull, but their effects can be mitigated with aberration correction. Simulating the cavitation detectors suggest variations in the sensitivity profile across the treatment volume and between patients. A correlation was observed with the cavitation dose, BBBD and petechial hemorrhage in 8/9 patients, but substantial variability was evident. Analysis of the cavitation spectra found that most bursts did not contain wideband emissions, a signature of inertial cavitation, but biggest contribution to the cavitation dose - the metric used to control the procedure - came from bursts with wideband emissions.
conclusionUsing a low subharmonic cavitation dose with a longer duration resulted in BBBD with minimal petechiae. The correlation between cavitation dose and outcomes demonstrates the benefits of feedback control based on acoustic emissions, although more work is needed to reduce variability. Acoustic simulations could improve focusing near the skull and inform our analysis of acoustic emissions. Monitoring additional frequency bands and improving the sensitivity of the cavitation detection could provide signatures of microbubble activity associated with BBB disruption that were undetected here and could improve our ability to achieve BBB disruption without vascular damage.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.