Evidence map›Paper›PMID 38895598›Full record

ArticleIEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division2024

Modeling and Control of an MR-Safe Pneumatic Radial Inflow Motor and Encoder (PRIME).

Anthony L Gunderman, Milad Azizkhani, Saikat Sengupta, Kevin Cleary, Yue Chen

Abstract read
In one paragraph

Article in IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Modeling and Control For Minimally Invasive Intracerebral Hemorrhage Evacuation.IEEE transactions on medical robotics and bionics · 2026
    Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Anthony L GundermanDepartment of Biomedical Engineering, Georgia Institute of Technology/Emory, Atlanta, GA 30338 USA.ORCID 0000-0002-8554-2970
Milad AzizkhaniDepartment of Biomedical Engineering, Georgia Institute of Technology/Emory, Atlanta, GA 30338 USA.ORCID 0000-0002-4451-886X
Saikat SenguptaVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232 USA.ORCID 0000-0001-5032-006X
Kevin ClearyChildren's National Hospital, Washington, DC 20010 USA.ORCID 0000-0001-9809-4823
Yue ChenDepartment of Biomedical Engineering, Georgia Institute of Technology/Emory, Atlanta, GA 30338 USA.ORCID 0000-0003-1350-4972

Funding

Improved arrhythmia ablation via MR-guided robotic catheterization and multimodal clinician feedbackR01EB034359 · NIBIB · GEORGIA INSTITUTE OF TECHNOLOGY · PI Yue Chen, Aravindan Kolandaivelu · 2023 to 2026
$2.5M
MRI-compatible concentric tube robot for intracerebral hemorrhageR01NS116148 · NINDS · CHILDREN'S RESEARCH INSTITUTE · PI CHEN, YUE, CLEARY, KEVIN R. · 2021 to 2024
$2.3M
NIBIB NIH HHS R01 EB034359NINDS NIH HHS R01 NS116148
6 · The paper itself

Abstract

Magnetic resonance (MR) conditional actuators and encoders are the key components for MR-guided robotic systems. In this article, we present the modeling and control of our MR-safe pneumatic radial inflow motor and encoder. A comprehensive model is developed that considers the primary dynamic elements of the system, including: 1) motor dynamics, 2) pneumatic transmission line dynamics, and 3) valve dynamics. After model validation, we present a simplified third order model that facilitates design of a first order sliding mode controller (TO-SMC). Finally, the motor hardware is tested in a 7T MRI. No image distortion or artifacts were observed. We posit the MR-safe motor and dynamic model will lower the entry barriers for researchers interested in MR-guided robots and promote wider adoption of MR-guided robotic systems.

Indexed as

Controlmagnetic resonance (MR) safemodelingpneumatic motor

Identifiers

PMID38895598
PMCPMC11185264

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked