Evidence map›Paper›PMID 38894959›Full record

ArticleAPL bioengineering2024

Parallel on-chip micropipettes enabling quantitative multiplexed characterization of vesicle mechanics and cell aggregates rheology.

Sylvain Landiech, Marianne Elias, Pierre Lapèze, Hajar Ajiyel, Marine Plancke, Blanca González-Bermúdez, Adrian Laborde, Fabien Mesnilgrente, David Bourrier, Debora Berti and 6 more

Abstract read
In one paragraph

Article in APL bioengineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Flippase-Mediated Hybrid Vesicle Division.Advanced materials (Deerfield Beach, Fla.) · 2025
    Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

Sylvain LandiechLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.ORCID https://orcid.org/0009-0004-1858-1912
Marianne EliasLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.
Pierre LapèzeLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.ORCID https://orcid.org/0009-0003-6290-8268
Hajar AjiyelLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.ORCID https://orcid.org/0009-0007-5645-7404
Marine PlanckeLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.
Blanca González-BermúdezCenter for Biomedical Technology, Universidad Politécnica de Madrid, Pozuelo de Alarcón, Spain and Department of Materials Science, ETSI de Caminos, Canales y Puertos, Universidad Politécnica de Madrid, Madrid, Spain.ORCID https://orcid.org/0000-0002-1266-0917
Adrian LabordeLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.
Fabien MesnilgrenteLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.ORCID https://orcid.org/0000-0001-9494-9986
David BourrierLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.
Debora BertiCSGI and Department of Chemistry, University of Florence, Sesto Fiorentino, Italy.ORCID https://orcid.org/0000-0001-8967-560X
Costanza MontisCSGI and Department of Chemistry, University of Florence, Sesto Fiorentino, Italy.ORCID https://orcid.org/0000-0001-6960-3772
Laurent MazenqLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.
Jérémy BaldoLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.
Clément RouxSoftMat, Université de Toulouse, CNRS, UPS, Toulouse, France.ORCID https://orcid.org/0000-0001-5707-4471
Morgan DelarueLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.ORCID https://orcid.org/0000-0003-1114-298X
Pierre JosephLAAS-CNRS, Université de Toulouse, CNRS, Toulouse, France.ORCID https://orcid.org/0000-0002-3142-8996

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Micropipette aspiration (MPA) is one of the gold standards for quantifying biological samples' mechanical properties, which are crucial from the cell membrane scale to the multicellular tissue. However, relying on the manipulation of individual home-made glass pipettes, MPA suffers from low throughput and no automation. Here, we introduce the sliding insert micropipette aspiration method, which permits parallelization and automation, thanks to the insertion of tubular pipettes, obtained by photolithography, within microfluidic channels. We show its application both at the lipid bilayer level, by probing vesicles to measure membrane bending and stretching moduli, and at the tissue level by quantifying the viscoelasticity of 3D cell aggregates. This approach opens the way to high-throughput, quantitative mechanical testing of many types of biological samples, from vesicles and individual cells to cell aggregates and explants, under dynamic physico-chemical stimuli.

Identifiers

PMID38894959
PMCPMC11184969

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.