ArticleSensors (Basel, Switzerland)2024
The Accuracy of Evaluation of the Requirements of the Standards IEC 61000-3-2(12) with the Application of the Wideband Current Transducer.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The aim of this paper is to determine the conversion accuracy of the Danisense DC200IF (Danisense A/S, Taastrup, Denmark) wideband current transducer for its possible application to test electromagnetic compatibility requirements of the standards IEC 61000-3-2 and IEC 61000-3-12 with the digital power meter Yokogawa WT5000 (Yokogawa Electric Corporation, Tokyo, Japan). To obtain this goal for distorted current of main frequency equal to 50 Hz and in the frequencies range of higher harmonics from 100 Hz to 2500 Hz its amplitude error and phase shift are evaluated. Moreover, the measurable level of higher harmonics with the rated accuracy of the used precision power analyzer is also investigated. Finally, the measuring system is applied to determine the RMS values of current harmonics produced by the audio power amplifier in order to assess its compliance with the standard IEC 61000-3-12.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.