Observational studySensors (Basel, Switzerland)2024
Efficacy of the Cardiac Implantable Electronic Device Multisensory Triage-HF Algorithm in Heart Failure Care: A Real-World Clinical Experience.
Observational study in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Real-World Diagnostic Performance for Heart Failure Events of TriageHFInternational journal of heart failure · 2026Article
- Equity at the Intersection of Heart Failure and Interventions: A Review of the Spectrum From Ambulatory Care to Cardiogenic Shock.Journal of the Society for Cardiovascular Angiography & Interventions · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Heart failure (HF) admissions are burdensome, and the mainstay of prevention is the timely detection of impending fluid retention, creating a window for medical treatment intensification. This study evaluated the accuracy and performance of a Triage-HF-guided carepath in real-world ambulatory HF patients in daily clinical practice. In this prospective, observational study, 92 adult HF patients (71 males (78%), with a median age of 69 [IQR 59-75] years) with the Triage-HF algorithm activated in their cardiac implantable electronic devices (CIEDs), were monitored. Following high-risk alerts, an HF nurse contacted patients to identify signs and symptoms of fluid retention. The sensitivity and specificity were 83% and 97%, respectively. The positive predictive value was 89%, and negative predictive value was 94%. The unexplained alert rate was 0.05 alerts/patient year, and the false negative rate was 0.11 alerts/patient year. Ambulatory diuretics were initiated or escalated in 77% of high-risk alert episodes. In 23% (n = 6), admission was ultimately required. The median alert handling time was 2 days. Fifty-eight percent (n = 18) of high-risk alerts were classified as true positives in the first week, followed by 29% in the second-third weeks (n = 9), and 13% (n = 4) in the fourth-sixth weeks. Common sensory triggers included an elevated night ventricular rate (84%), OptiVol (71%), and reduced patient activity (71%). The CIED-based Triage-HF algorithm-driven carepath enables the timely detection of impending fluid retention in a contemporary ambulatory setting, providing an opportunity for clinical action.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.