Evidence map›Paper›PMID 38894440›Full record

ArticleSensors (Basel, Switzerland)2024

Detection of Low-Concentration Biological Samples Based on a QBIC Terahertz Metamaterial Sensor.

Bing Dong, Bo Wei, Dongshan Wei, Zhilin Ke, Dongxiong Ling

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. A Dual-Channel Synergistic Ultrasensitive Biosensor for Tumor Liquid Biopsy.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Bing DongSchool of Electrical Engineering and Intelligentization, Dongguan University of Technology, Dongguan 523808, China.
Bo WeiSchool of Physics and Optoelectronic Engineering, Yangtze University, Jingzhou 434023, China.
Dongshan WeiShenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.ORCID 0000-0003-3999-3911
Zhilin KeSchool of Electrical Engineering and Intelligentization, Dongguan University of Technology, Dongguan 523808, China.
Dongxiong LingSchool of Electrical Engineering and Intelligentization, Dongguan University of Technology, Dongguan 523808, China.

Funding

Guangdong Basic and Applied Basic Research Foundation 2021B1515140018Major Instrumentation Development Program of the Chinese Academy of Sciences ZDKYYQ20220008
6 · The paper itself

Abstract

Quasi-bound state in the continuum (QBIC) can effectively enhance the interaction of terahertz (THz) wave with matter due to the tunable high-Q property, which has a strong potential application in the detection of low-concentration biological samples in the THz band. In this paper, a novel THz metamaterial sensor with a double-chain-separated resonant cavity structure based on QBIC is designed and fabricated. The process of excitation of the QBIC mode is verified and the structural parameters are optimized after considering the ohmic loss by simulations. The simulated refractive index sensitivity of the sensor is up to 544 GHz/RIU, much higher than those of recently reported THz metamaterial sensors. The sensitivity of the proposed metamaterial sensor is confirmed in an experiment by detecting low-concentration lithium citrate (LC) and bovine serum albumin (BSA) solutions. The limits of detection (LoDs) are obtained to be 0.0025 mg/mL (12 μM) for LC and 0.03125 mg/mL (0.47 μM) for BSA, respectively, both of which excel over most of the reported results in previous studies. These results indicate that the proposed THz metamaterial sensor has excellent sensing performances and can well be applied to the detection of low-concentration biological samples.

Indexed as

Biosensing TechniquesSerum Albumin, BovineAnimalsCattleCitric AcidLimit of DetectionLithium CompoundsRefractometryTerahertz RadiationTerahertz SpectroscopyCitric AcidLithium CompoundsSerum Albumin, Bovinebovine serum albuminlimit of detectionlithium citratemetamaterial sensorQuasi-bound state in the continuumterahertz

Identifiers

PMID38894440
PMCPMC11175237

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.