Evidence map›Paper›PMID 38894339›Full record

ArticleSensors (Basel, Switzerland)2024

Evaluation of Lateral Radar Positioning for Vital Sign Monitoring: An Empirical Study.

Lars Hornig, Benedek Szmola, Wiebke Pätzold, Jan Paul Vox, Karen Insa Wolf

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lars HornigFraunhofer Institute for Digital Media Technology IDMT, Oldenburg Branch for Hearing, Speech and Audio Technology HSA, Marie-Curie-Straße 2, 26129 Oldenburg, Germany.ORCID 0009-0003-2508-9785
Benedek SzmolaFraunhofer Institute for Digital Media Technology IDMT, Oldenburg Branch for Hearing, Speech and Audio Technology HSA, Marie-Curie-Straße 2, 26129 Oldenburg, Germany.ORCID 0009-0000-5365-8779
Wiebke PätzoldFraunhofer Institute for Digital Media Technology IDMT, Oldenburg Branch for Hearing, Speech and Audio Technology HSA, Marie-Curie-Straße 2, 26129 Oldenburg, Germany.ORCID 0000-0002-2087-9353
Jan Paul VoxFraunhofer Institute for Digital Media Technology IDMT, Oldenburg Branch for Hearing, Speech and Audio Technology HSA, Marie-Curie-Straße 2, 26129 Oldenburg, Germany.ORCID 0000-0003-3699-3414
Karen Insa WolfFraunhofer Institute for Digital Media Technology IDMT, Oldenburg Branch for Hearing, Speech and Audio Technology HSA, Marie-Curie-Straße 2, 26129 Oldenburg, Germany.ORCID 0000-0001-8739-5532

Funding

Niedersächsisches Ministerium für Wissenschaft und Kultur; Volkswagen Foundation Record token 11 - 454 76251-2005/2021 (ZN 3503)
6 · The paper itself

Abstract

Vital sign monitoring is dominated by precise but costly contact-based sensors. Contactless devices such as radars provide a promising alternative. In this article, the effects of lateral radar positions on breathing and heartbeat extraction are evaluated based on a sleep study. A lateral radar position is a radar placement from which multiple human body zones are mapped onto different radar range sections. These body zones can be used to extract breathing and heartbeat motions independently from one another via these different range sections. Radars were positioned above the bed as a conventional approach and on a bedside table as well as at the foot end of the bed as lateral positions. These positions were evaluated based on six nights of sleep collected from healthy volunteers with polysomnography (PSG) as a reference system. For breathing extraction, comparable results were observed for all three radar positions. For heartbeat extraction, a higher level of agreement between the radar foot end position and the PSG was found. An example of the distinction between thoracic and abdominal breathing using a lateral radar position is shown. Lateral radar positions could lead to a more detailed analysis of movements along the body, with the potential for diagnostic applications.

Indexed as

Heart RateRadarRespirationVital SignsAdultFemaleHumansMaleMonitoring, PhysiologicPolysomnographybreathing ratefrequency-modulated continuous wave (FMCW)heart rateradarsleep monitoringvital signs

Identifiers

PMID38894339
PMCPMC11175299

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390