Evidence map›Paper›PMID 38894084›Full record

ArticleSensors (Basel, Switzerland)2024

Research on an SICM Scanning Image Resolution Enhancement Algorithm.

Zhenhua Quan, Shilin Xu, Xiaobo Liao, Bin Wu, Liang Luo

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Zhenhua QuanSchool of Information Engineering, Southwest University of Science and Technology, Mianyang 621010, China.
Shilin XuSchool of Information Engineering, Southwest University of Science and Technology, Mianyang 621010, China.
Xiaobo LiaoSchool of Information Engineering, Southwest University of Science and Technology, Mianyang 621010, China.
Bin WuSchool of Information Engineering, Southwest University of Science and Technology, Mianyang 621010, China.
Liang LuoSchool of Information Engineering, Southwest University of Science and Technology, Mianyang 621010, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Scanning ion conductance microscopy (SICM) enables the non-invasive three-dimensional imaging of live cells and other structures in physiological environments. However, when imaging complex samples, SICM faces challenges such as having a low temporal resolution during slow scanning and a reduced signal-to-noise ratio during fast scanning, making it difficult to simultaneously improve both temporal and spatial resolution. To address these issues, this paper proposes an algorithm for enhancing image resolution under high-speed scanning. Firstly, scanning images are preprocessed using a median filtering algorithm to remove the salt-and-pepper noise generated during high-speed scanning. Next, the Canny edge detection algorithm is employed to extract the edges of the image targets. To avoid blurring the edges, the new edge-directed interpolation (NEDI) algorithm is then used to fill the edges, while non-edge areas are filled using bilinear interpolation, thereby enhancing the image resolution. Finally, the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) are used to analyze the imaging of articular chondrocytes. The results show that under a scanning speed of 480 nm/ms, the proposed algorithm improves the temporal resolution of imaging by 60% compared to traditional 2× resolution imaging, increases the peak signal-to-noise ratio of the scanning images by 7 dB, and achieves a structural similarity of 0.97. Therefore, the proposed algorithm effectively removes noise during high-speed scanning and improves the SICM scanning imaging resolution, thereby avoiding the reduction in temporal resolution when scanning larger resolution samples and effectively enhancing the performance of SICM scanning imaging.

Indexed as

NEDIscanning imaging resolution enhancementscanning ion conductance microscopy

Identifiers

PMID38894084
PMCPMC11174451

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.