ArticleFoods (Basel, Switzerland)2024
Feasibility of Matrix-Matched Material for Determining Elements in Rice Flour by SN-ICP-MS and LA-ICP-MS.
Article in Foods (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The preparation of matrix-matched material for elemental quantitative analysis in rice flour matrix is proposed here for the first time as part of a feasibility study using the SN-ICP-MS and LA-ICP-MS methods. It was prepared via the spiking process in colloidal solution of rice flour with different levels of arsenic (As), cadmium (Cd) and lead (Pb), followed by drying in a climatic chamber. Comparative studies of the results on external calibration and gravimetric standard addition ICP-MS approaches through the use of calibration standard solutions were discussed. Method bias from the external calibration method was investigated, demonstrating the systematic effect arising from the sample matrix. Characterizing the concentration of measurands was then reasonably proposed using the gravimetric standard addition ICP-MS. Using powdered rice matrix reference material for ICP-MS calibration following acid digestion, the study showed a good agreement of recovery studies. A feasibility study of the LA-ICP-MS method as a direct solid analysis performed on the matrix-matched standard was then discussed. In the study, large fluctuation of signals was found for constructing calibration curve, generating poor linearity, especially for As and Pb, although yttrium (Y) as internal standard was applied. This might be ascribed to a limited microscale of homogeneity, and particularly laser-induced preferential evaporation of volatile elements. Using a number of measured data points, the mean and median were statistically recommended to improve precision. An attempt to use of similar matrix in both standard and sample is a critical point to consider to minimize the elemental fractionation effect. The proposed approach to prepare matrix-matched material could be a potential means for achieving elemental quantitation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.