Evidence map›Paper›PMID 38890168›Full record

ArticleClinical oral investigations2024

Accuracy of an autonomous dental implant robotic system in partial edentulism: A pilot clinical study.

MiaoZhen Wang, Feng Liu, Tao Yu, Yalin Zhan, Feifei Ma, Xiaohui Rausch-Fan

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

MiaoZhen WangFirst Clinical Division, Peking University School and Hospital for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology for Stomatology & Beijing Key Laboratory for Digital Stomatology, Beijing, PR China.
Feng LiuFirst Clinical Division, Peking University School and Hospital for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology for Stomatology & Beijing Key Laboratory for Digital Stomatology, Beijing, PR China. dentistliufeng@126.com.
Tao YuFirst Clinical Division, Peking University School and Hospital for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology for Stomatology & Beijing Key Laboratory for Digital Stomatology, Beijing, PR China.
Yalin ZhanFirst Clinical Division, Peking University School and Hospital for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology for Stomatology & Beijing Key Laboratory for Digital Stomatology, Beijing, PR China.
Feifei MaFirst Clinical Division, Peking University School and Hospital for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology for Stomatology & Beijing Key Laboratory for Digital Stomatology, Beijing, PR China.
Xiaohui Rausch-FanDivision of Conservative Dentistry and Periodontology, Center of Clinical Research, Dental School, Medical University of Vienna, Vienna, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesRobots are increasingly being used for surgical procedures in various specialties. However, information about the accuracy of robot-assisted dental implant surgery is lacking. This pilot clinical study aimed to investigate the accuracy of an autonomous dental implant robotic (ADIR) system in partially edentulous cases. MATERIAL AND

methodsThe ADIR system was used to place a total of 20 implants in 13 participants. Implant deviation from the planned positions was assessed to determine accuracy. The entry, apex, and angular deviations were described as means ± standard deviation. A two-sample t test was used to compare implant deviation between the flap and flapless groups and between maxillary and mandibular implants (α = .05).

resultsThe entry, apex, and angular deviations were 0.65 ± 0.32 mm, 0.66 ± 0.34 mm, and 1.52 ± 1.01°, respectively, with no statistically significant difference between the flap and flapless approaches (P > .05). No adverse events were encountered in any of the participants.

conclusionsDIR accuracy in this clinical series was comparable to that reported for static and dynamic computer-assisted implant surgery. Robotic computer-assisted implant surgery may be useful for dental implant placement, potentially improving the quality and safety of the procedure. CLINICAL RELEVANCE: The findings of this study showed that the ADIR system could be useful for dental implant surgery.

Indexed as

Dental Implantation, EndosseousJaw, Edentulous, PartiallyAdultDental ImplantsFemaleHumansMaleMiddle AgedPilot ProjectsRobotic Surgical ProceduresTreatment OutcomeDental ImplantsAccuracyAutonomous dental implant roboticDeviationImplant

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.