ArticleThe journal of extra-corporeal technology2024
Quantifying potential fluid transfused through pressure monitoring and circuit flushes in pediatric ECMO patients.
Article in The journal of extra-corporeal technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Pressure monitoring on pediatric Extracorporeal Membrane Oxygenation (ECMO) circuits is used to aid in the evaluation of patient hemodynamics and circuit health. Extracorporeal Life Support Organization (ELSO) recommends monitoring pressures on the venous line, pre-, and post-oxygenator. In order to keep pressure ports patent, crystalloid can be used as a flush. The fluid transfused to the patient through these lines can be challenging to quantify accurately due to variance in clinician practice. Currently, there is no published data or practice suggestions on this topic. In Vitro experiments using Edwards True Wave transducers and pressure bags were constructed, allowing for common negative and positive pressures to be simulated. Passive volume infused through the transducer as well as intermittent active flushing by pulling the snap tab were measured and the volumes were recorded. When the pressure transducer and associated tubing are kept patent by using a pressurized IV bag, per the instructions for use, the daily volume transfused was found to be 319.6 mL or close to a typical neonate's total blood volume. Rather than using passive or active flushing, the use of automated syringe pumps can reduce the transfused volume to 24 mL per day. Further study is recommended to develop and publish best practices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.