Evidence map›Paper›PMID 38884668›Full record

ArticlePhysical and engineering sciences in medicine2024

Super-resolution deep-learning reconstruction for cardiac CT: impact of radiation dose and focal spot size on task-based image quality.

Takafumi Emoto, Yasunori Nagayama, Sentaro Takada, Daisuke Sakabe, Shinsuke Shigematsu, Makoto Goto, Kengo Nakato, Ryuya Yoshida, Ryota Harai, Masafumi Kidoh and 3 more

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Takafumi Emoto *Department of Central Radiology, Kumamoto University Hospital, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Yasunori Nagayama *Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan. nagayama.yasunori@kuh.kumamoto-u.ac.jp.ORCID http://orcid.org/0000-0003-3280-7346
Sentaro TakadaDepartment of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Daisuke SakabeDepartment of Central Radiology, Kumamoto University Hospital, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Shinsuke ShigematsuDepartment of Central Radiology, Kumamoto University Hospital, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Makoto GotoDepartment of Central Radiology, Kumamoto University Hospital, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Kengo NakatoDepartment of Central Radiology, Kumamoto University Hospital, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Ryuya YoshidaDepartment of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Ryota HaraiDepartment of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Masafumi KidohDepartment of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Seitaro OdaDepartment of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Takeshi NakauraDepartment of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
Toshinori HiraiDepartment of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.

Funding

Japan Society for the Promotion of Science KAKENHI 23K14873
6 · The paper itself

Abstract

This study aimed to evaluate the impact of radiation dose and focal spot size on the image quality of super-resolution deep-learning reconstruction (SR-DLR) in comparison with iterative reconstruction (IR) and normal-resolution DLR (NR-DLR) algorithms for cardiac CT. Catphan-700 phantom was scanned on a 320-row scanner at six radiation doses (small and large focal spots at 1.4-4.3 and 5.8-8.8 mGy, respectively). Images were reconstructed using hybrid-IR, model-based-IR, NR-DLR, and SR-DLR algorithms. Noise properties were evaluated through plotting noise power spectrum (NPS). Spatial resolution was quantified with task-based transfer function (TTF); Polystyrene, Delrin, and Bone-50% inserts were used for low-, intermediate, and high-contrast spatial resolution. The detectability index (d') was calculated. Image noise, noise texture, edge sharpness of low- and intermediate-contrast objects, delineation of fine high-contrast objects, and overall quality of four reconstructions were visually ranked. Results indicated that among four reconstructions, SR-DLR yielded the lowest noise magnitude and NPS peak, as well as the highest average NPS frequency, TTF

Indexed as

Deep LearningImage Processing, Computer-AssistedPhantoms, ImagingRadiation DosageTomography, X-Ray ComputedAlgorithmsHeartHumansSignal-To-Noise RatioMultidetector computed tomographySpatial resolutionSuper-resolution deep learning image reconstruction algorithmTask-based image quality assessment

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.