ArticleJournal of thoracic disease2024
The safety and feasibility of mini-invasive Bentall surgery via right anterior mini-thoracotomy.
Article in Journal of thoracic disease, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Transaxillary access for ascending aortic and root surgery: a single-center comparison with full and partial sternotomy.Annals of cardiothoracic surgery · 2026Article
- Single-center experience of minimally invasive ascending aortic surgery via right anterior mini-thoracotomy.Journal of cardiothoracic surgery · 2026Article
- Evaluating the Efficacy of Automated Suturing Technology for Bentall Procedures in a Passive Beating Heart Model.Innovations (Philadelphia, Pa.)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The right anterior mini-thoracotomy (RAMT) approach has become a popular technique in cardiac surgery and applied in valve surgery. However, there is very limited evidence on the application of RAMT in the Bentall surgery. In the present study, we aimed to evaluate the safety and feasibility of the RAMT approach in Bentall surgery. Methods: A retrospective analysis was performed on 27 patients who underwent Bentall surgery between September 2020 and April 2022 in the First Affiliated Hospital of Xi'an Jiaotong University. Follow-ups were undertaken 1 and 6 months after their operations. The baseline, perioperative, and follow-up results were retrospectively analyzed. Results: A total of 27 male patients aged 48-61 years were included in the study. The operation time ranged from 4.0 to 5.0 hours, with a median of 4.5 hours. The median aortic cross-clamping time was 122 minutes [interquartile range (IQR): 109-145 minutes], and the median cardiopulmonary bypass (CPB) time was 156 minutes (IQR: 143-183 minutes). The median intensive care unit stay was 3 days (IQR: 1.75-4.25 days). The ventilation time ranged from 6.5 to 22.0 hours, with a median of 13.0 hours. The median drainage volume in the first 24 hours was 210 mL. In the following-up data, no deaths or severe complications were observed. Conclusions: The mini-Bentall procedure through an RAMT approach is a feasible and safe approach with few wounds and good clinical results in patients undergoing aortic root replacement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.