ArticleCureus2024
The Production, Assessment, and Utility of 3D-Printed Video Laryngoscopes in Eastern India: A Low-Cost Alternative to Conventional Video Laryngoscopes.
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Tiny airways, high stakes: What every clinician should know about infant airway management in 2025.Indian journal of anaesthesia · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction Recognizing the limitations of traditional direct laryngoscopes, particularly in difficult airway situations, video laryngoscopy has emerged as a potentially safer and more effective alternative. This study evaluated the utility of two 3D-printed video laryngoscopes: a standard geometry video laryngoscope (SGVL), resembling the traditional Macintosh blade, and a hyper-angulated video laryngoscope (HAVL) with a more curved design. Their performance was compared to a standard Macintosh direct laryngoscope across various intubation parameters. By leveraging the cost-effectiveness of 3D printing with polylactic acid, the study aimed to assess the potential of this technology to improve airway management across diverse clinical settings and varying levels of physician expertise. Methods This prospective randomized crossover study compared the effectiveness of 3D-printed video laryngoscopes (VL) and a standard direct laryngoscope in intubation. After obtaining IRB approval, physicians from various specialties across multiple centers participated. Participants received training on SGVL, HAVL, and DL intubation using an instructional video and hands-on practice. The training was standardized for all participants. The primary outcome measures were time to successful intubation, number of attempts, and time to visualize vocal cords. Participants were randomized to use all three laryngoscopes on a manikin, with a maximum of two attempts per scope. A 30-minute break separated each laryngoscope evaluation. Successful intubation was defined as the single insertion of each laryngoscope and bougie, followed by endotracheal tube placement and confirmation of lung inflation. Results Ninety-eight doctors, mostly from the EM team (73.5%) and ICU team (23.4%). Teams consist of consultants, residents, and medical officers of the concerned departments. Forty-eight of the participants (49%) were novice operators (<25 intubations). Successful first-attempt intubation in those with <1 year of experience with intubation (n=33) was highest for SGVL (97%) compared to DL (82%) and HAVL (67%). Participants who learned intubation through self-directed learning exhibited a higher acceptance of VL and achieved 100% success on their first attempt. Among those who followed modules or workshops, 97% had successful first-attempt intubation with VL. The average time taken to visualize the vocal cords was lower in SGVL compared to DL (5.6 vs. 7.5 seconds) (p<0.001). The HAVL also had a lower average time compared to the DL (7.1 vs. 7.5 secs) (p<0.001). However, the time taken to intubate using DL (24.2 ±8.7 sec) was similar to SGVL (28.1 ±13 sec). Lastly, the intubation time using HAVL was the longest (49.6 ±35.5 sec). The time to intubate with DL and SGVL had Spearman's rho of 0.64 (p<0.001), and DL and HAVL had 0.59 (p<0.001). Conclusions The ease of use and its cost-effective nature make 3D-printed VLs beneficial in situations where traditional VLs may not be available, especially in simulation and training.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.