Evidence map›Paper›PMID 38882985›Full record

ArticleCureus2024

Development of Augmented Reality Vision for Osteosynthesis Using a 3D Camera.

Junichiro Morita, Akira Ikumi, Takushi Nakatani, Hiroshi Noguchi, Hajime Mishima, Tomoo Ishii, Yuichi Yoshii

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Junichiro MoritaGraduate School of Medicine, University of Tsukuba, Tsukuba, JPN.
Akira IkumiDepartment of Orthopaedic Surgery, University of Tsukuba, Tsukuba, JPN.
Takushi NakataniDepartment of Orthopaedic Surgery, Showa General Hospital, Kodaira, JPN.
Hiroshi NoguchiDepartment of Orthopaedic Surgery, University of Tsukuba, Tsukuba, JPN.
Hajime MishimaDepartment of Orthopaedic Surgery, University of Tsukuba, Tsukuba, JPN.
Tomoo IshiiDepartment of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, Ami, JPN.
Yuichi YoshiiDepartment of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, Ami, JPN.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe developed a 3D camera system to track motion in a surgical field. This system has the potential to introduce augmented reality (AR) systems non-invasively, eliminating the need for the invasive AR markers conventionally required. The present study was performed to verify the real-time tracking accuracy of this system, assess the feasibility of integrating this system into the surgical workflow, and establish its potential to enhance the accuracy and efficiency of orthopedic procedures.

methodsTo evaluate the accuracy of AR technology using a 3D camera, a forearm bone model was created. The forearm model was depicted using a 3D camera, and its accuracy was verified in terms of the positional relationship with a 3D bone model created from previously imaged CT data. Images of the surgical field (capturing the actual forearm) were taken and saved in nine poses by rotating the forearm from pronation to supination. The alignment of the reference points was computed at the three points of CT versus the three points of the 3D camera, yielding a 3D rotation matrix representing the positional relationship. In the original system, a stereo vision-based 3D camera, with a depth image resolution of 1280×720 pixels, 30 frames per second, and a lens field of view of 64 specifications, with a baseline of 3 cm, capable of optimally acquiring real-time 3D data at a distance of 40-60 cm from the subject was used. In the modified system, the following modifications were made to improve tracking performance: (1) color filter processing was changed from HSV to RGB, (2) positional detection accuracy was modified with supporting marker sizes of 8 mm in diameter, and (3) the detection of marker positions was stabilized by calculating the marker position for each frame. Tracking accuracy was examined with the original system and modified system for the following parameters: differences in the rotation matrix, maximum and minimum inter-reference point errors between CT-based and camera-based 3D data, and the average error for the three reference points.

resultsIn the original system, the average difference in rotation matrices was 5.51±2.68 mm. Average minimum and maximum errors were 1.10±0.61 and 15.53±12.51 mm, respectively. The average error of reference points was 6.26±4.49 mm. In the modified system, the average difference in rotation matrices was 4.22±1.73 mm. Average minimum and maximum errors were 0.79±0.49 and 1.94±0.87 mm, respectively. The average error of reference points was 1.41±0.58 mm. In the original system, once tracking failed, it was difficult to recover tracking accuracy. This resulted in a large maximum error in supination positions. These issues were resolved by the modified system. Significant improvements were achieved in maximum errors and average errors using the modified system (P<0.05).

conclusionAR technology using a 3D camera was developed. This system allows direct comparisons of 3D data from preoperative CT scans with 3D data acquired from the surgical field using a 3D camera. This method has the advantage of introducing AR into the surgical field without invasive markers.

Indexed as

3d cameraaugmented reality (ar)computed tomographyosteosynthesispreoperative plan

Identifiers

PMID38882985
PMCPMC11180535

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.