Evidence map›Paper›PMID 38882102›Full record

ArticleACS omega2024

Electrochemical Degradation of Molecularly Imprinted Polymers for Future Applications of Inflammation Sensing in Cochlear Implants.

Minh-Hai Nguyen, Adrian Onken, Jan Sündermann, Madina Shamsuyeva, Pankaj Singla, Tom Depuydt, Marloes Peeters, Patrick Wagner, Konrad Bethmann, Julia Körner and 3 more

Abstract read
In one paragraph

Article in ACS omega, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Minh-Hai NguyenDepartment of Otolaryngology and Cluster of Excellence "Hearing4all", Hannover Medical School, Carl-Neuberg-Straße 1, 30625 Hannover, Germany.ORCID https://orcid.org/0009-0009-4175-3002
Adrian OnkenDepartment of Otolaryngology and Cluster of Excellence "Hearing4all", Hannover Medical School, Carl-Neuberg-Straße 1, 30625 Hannover, Germany.
Jan SündermannDepartment of Chemical Safety and Toxicology, Fraunhofer Institute of Toxicology and Experimental Medicine ITEM, Nikolai-Fuchs-Straße 1, 30625 Hannover, Germany.
Madina ShamsuyevaIKK - Institute of Plastics and Circular Economy, Leibniz University Hannover, An der Universität 2, 30823 Garbsen, Germany.
Pankaj SinglaEngineering Department, University of Manchester, Engineering A building, Booth E Street, M13 9QS Manchester, United Kingdom.
Tom DepuydtLaboratory for Soft Matter and Biophysics, KU Leuven, Celestijnenlaan 200D, Leuven B-3001, Belgium.
Marloes PeetersEngineering Department, University of Manchester, Engineering A building, Booth E Street, M13 9QS Manchester, United Kingdom.ORCID https://orcid.org/0000-0002-0429-8073
Patrick WagnerLaboratory for Soft Matter and Biophysics, KU Leuven, Celestijnenlaan 200D, Leuven B-3001, Belgium.ORCID https://orcid.org/0000-0002-4028-3629
Konrad BethmannDepartment of Information processing, Leibniz University Hannover, Welfengarten 1, 30167 Hannover, Germany.
Julia KörnerInstitute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Appelstraße 9a, 30167 Hannover, Germany.
Hans-Josef EndresIKK - Institute of Plastics and Circular Economy, Leibniz University Hannover, An der Universität 2, 30823 Garbsen, Germany.
Thomas LenarzDepartment of Otolaryngology and Cluster of Excellence "Hearing4all", Hannover Medical School, Carl-Neuberg-Straße 1, 30625 Hannover, Germany.
Theodor DollDepartment of Otolaryngology and Cluster of Excellence "Hearing4all", Hannover Medical School, Carl-Neuberg-Straße 1, 30625 Hannover, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

After cochlear implant (CI) insertion, there is a possibility of postoperative inflammation, which may involve proinflammatory markers such as interleukin-6. Detecting this inflammation promptly is crucial for administering anti-inflammatory drugs, if required. One potential method for detecting inflammation is using molecular imprinted polymers (MIPs). These MIPs, which can be deposited on the CI electrode, provide readout employing impedance measurements, a feature already available on the CI circuit. MIPs designed for this purpose should possess biocompatibility, conductivity, and degradability. The degradability is crucial because there is a limitation on the number of electrodes available, and once the inflammation sensor degrades after the acute inflammation period, it should remain usable as a regular electrode. In this work, conductive poly(3,4-ethylenedioxythiophene) polystyrenesulfonate-based MIPs were synthesized against biotin as a surrogate target marker. Specific biotin binding with MIPs was determined before and after degradation using electrochemical impedance spectroscopy (EIS) and compared with the control nonimprinted polymers (NIPs). Subsequently, MIPs were electrochemically degraded by EIS with different potentials, wherein a potential dependence was observed. With decreasing potential, fewer dissolved polymers and more monomer molecules were detected in the solution in which degradation took place. At a potential of 0.205 V a negligible amount of dissolved polymer in addition to the dissolved monomer molecules was measured, which can be defined as the limiting potential. Below this potential, only dissolved monomer molecules are obtained, which enables renal clearance. Biocompatibility testing revealed that both the polymer and the solution with dissolved monomer molecules do not exceed the ISO 10993-5 cytotoxicity threshold. Based on these findings, we have developed conductive, biocompatible, and controllably degradable MIPs capable of detecting biotin. This research work paves the way for the advancement of CIs, where inflammation can be detected using molecular imprinting technology without compromising the stability and biosafety of the product.

Identifiers

PMID38882102
PMCPMC11170751

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.