ArticleInternational journal of retina and vitreous2024

Image quality comparison of AirDoc portable retina camera versus eyer in a diabetic retinopathy screening program.

Rodrigo Brant, Luis Filipe Nakayama, Talita Virgínia Fernandes de Oliveira, Juliana Angelica Estevão de Oliveira, Lucas Zago Ribeiro, Gabriela Dalmedico Richter, Rafael Rodacki, Fernando Marcondes Penha

Abstract readLetter
In one paragraph

Article in International journal of retina and vitreous, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Rodrigo Brant *Ophthalmology and Visual Science Department, Sao Paulo Federal University, Sao Paulo, SP, Brazil. rodrigo.fernandes@med.usc.edu.
Luis Filipe Nakayama *Ophthalmology and Visual Science Department, Sao Paulo Federal University, Sao Paulo, SP, Brazil.
Talita Virgínia Fernandes de OliveiraOphthalmology and Visual Science Department, Sao Paulo Federal University, Sao Paulo, SP, Brazil.
Juliana Angelica Estevão de OliveiraOphthalmology and Visual Science Department, Sao Paulo Federal University, Sao Paulo, SP, Brazil.
Lucas Zago RibeiroOphthalmology and Visual Science Department, Sao Paulo Federal University, Sao Paulo, SP, Brazil.
Gabriela Dalmedico RichterFundação Universidade Regional de Blumenau, Blumenau, SC, Brazil.
Rafael RodackiFundação Universidade Regional de Blumenau, Blumenau, SC, Brazil.
Fernando Marcondes PenhaFundação Universidade Regional de Blumenau, Blumenau, SC, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDiabetic retinopathy (DR) stands as the foremost cause of preventable blindness in adults. Despite efforts to expand DR screening coverage in the Brazilian public healthcare system, challenges persist due to various factors including social, medical, and financial constraints. Our objective was to evaluate the quality of images obtained with the AirDoc, a novel device, compared to Eyer portable camera which has already been clinically validated.

methodsImages were captured by two portable retinal devices: AirDoc and Eyer. The included patients had their fundus images obtained in a screening program conducted in Blumenau, Santa Catarina. Two retina specialists independently assessed image's quality. A comparison was performed between both devices regarding image quality and the presence of artifacts.

resultsThe analysis included 129 patients (mean age of 61 years), with 29 (43.28%) male and an average disease duration of 11.1 ± 8 years. In Ardoc, 21 (16.28%) images were classified as poor quality, with 88 (68%) presenting artifacts; in Eyer, 4 (3.1%) images were classified as poor quality, with 94 (72.87%) presenting artifacts.

conclusionsAlthough both Eyer and AirDoc devices show potential as screening tools, the AirDoc images displayed higher rates of ungradable and low-quality images, that may directly affect the DR and DME grading. We must acknowledge the limitations of our study, including the relatively small sample size. Therefore, the interpretations of our analyses should be approached with caution, and further investigations with larger patient cohorts are warranted to validate our findings.

Indexed as

Diabetic retinopathyImage qualityPortable retinal camerasRetina