Evidence map›Paper›PMID 38875670›Full record

ArticleJMIR biomedical engineering2023

Continuous Critical Respiratory Parameter Measurements Using a Single Low-Cost Relative Humidity Sensor: Evaluation Study.

Fabrice Vaussenat, Abhiroop Bhattacharya, Julie Payette, Jaime A Benavides-Guerrero, Alexandre Perrotton, Luis Felipe Gerlein, Sylvain G Cloutier

Abstract read
In one paragraph

Article in JMIR biomedical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Fabrice VaussenatDepartment of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada.ORCID https://orcid.org/0009-0004-1267-2952
Abhiroop BhattacharyaDepartment of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada.ORCID https://orcid.org/0000-0003-2883-0754
Julie PayetteDepartment of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada.ORCID https://orcid.org/0009-0008-9402-4172
Jaime A Benavides-GuerreroDepartment of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada.ORCID https://orcid.org/0000-0002-9284-239X
Alexandre PerrottonDepartment of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada.ORCID https://orcid.org/0009-0007-1510-0062
Luis Felipe GerleinDepartment of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada.ORCID https://orcid.org/0000-0001-6188-5330
Sylvain G CloutierDepartment of Electrical Engineering, École de Technologie Supérieure, Montreal, QC, Canada.ORCID https://orcid.org/0000-0003-0092-5241

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccurate and portable respiratory parameter measurements are critical for properly managing chronic obstructive pulmonary diseases (COPDs) such as asthma or sleep apnea, as well as controlling ventilation for patients in intensive care units, during surgical procedures, or when using a positive airway pressure device for sleep apnea.

objectiveThe purpose of this research is to develop a new nonprescription portable measurement device that utilizes relative humidity sensors (RHS) to accurately measure key respiratory parameters at a cost that is approximately 10 times less than the industry standard.

methodsWe present the development, implementation, and assessment of a wearable respiratory measurement device using the commercial Bosch BME280 RHS. In the initial stage, the RHS was connected to the pneumotach (PNT) gold standard device via its external connector to gather breathing metrics. Data collection was facilitated using the Arduino platform with a Bluetooth Low Energy connection, and all measurements were taken in real time without any additional data processing. The device's efficacy was tested with 7 participants (5 men and 2 women), all in good health. In the subsequent phase, we specifically focused on comparing breathing cycle and respiratory rate measurements and determining the tidal volume by calculating the region between inhalation and exhalation peaks. Each participant's data were recorded over a span of 15 minutes. After the experiment, detailed statistical analysis was conducted using ANOVA and Bland-Altman to examine the accuracy and efficiency of our wearable device compared with the traditional methods.

resultsThe perfused air measured with the respiratory monitor enables clinicians to evaluate the absolute value of the tidal volume during ventilation of a patient. In contrast, directly connecting our RHS device to the surgical mask facilitates continuous lung volume monitoring. The results of the 1-way ANOVA showed high P values of .68 for respiratory volume and .89 for respiratory rate, which indicate that the group averages with the PNT standard are equivalent to those with our RHS platform, within the error margins of a typical instrument. Furthermore, analysis utilizing the Bland-Altman statistical method revealed a small bias of 0.03 with limits of agreement (LoAs) of -0.25 and 0.33. The RR bias was 0.018, and the LoAs were -1.89 and 1.89.

conclusionsBased on the encouraging results, we conclude that our proposed design can be a viable, low-cost wearable medical device for pulmonary parametric measurement to prevent and predict the progression of pulmonary diseases. We believe that this will encourage the research community to investigate the application of RHS for monitoring the pulmonary health of individuals.

Indexed as

airbreathingCOPDdesigndevelopdevelopmenthumiditymedical devicepulmonarypulmonary volumerelative humidity sensorrespiratorysensorsensorstidal volumeventilationwearablewearables

Identifiers

PMID38875670
PMCPMC11041423

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.