ArticleJournal of fluorescence2025
Fluorescent Carbon Nitride Nanoparticles for Picric Acid Sensing.
Article in Journal of fluorescence, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Pyrazoline-Based Fluorescent Sensor for Picric Acid Detection in Aqueous Media: Experimental and DFT Insights.Journal of fluorescence · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Detection of nitroaromatic explosives is essential in the area of environmental safety. Fluorescent carbon nitride nanoparticles is a promising material for this purpose. Herein, we have prepared fluorescent carbon nitride nanoparticles (CNNPs) by one step thermal treatment of formamide. These fluorescent CNNPs is sensitive towards picric acid (PA) than other analytes both in aqueous medium and on test paper which is witnessed by fluorescence quenching based on inner filter effect (IFE). The PA detection with the fluorescent CNNPs is observed in the concentration ranges, 0 µM to 60 µM with linear range of 10 nM to 25 µM. The minimum detection limit in aqueous medium and solid phase are determined to be 26.20 nM and 10 µM respectively. Finally, the fluorescent CNNPs is applied for detection of PA in real water samples. The recoveries are in the ranges from 99.54 to 116.35% with relative standard deviation less than 3.85%. This proposed fluorescent method can act as suitable analytical technique to monitored PA concentration in water samples.
Indexed as
Identifiers
38874826What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.