Evidence map›Paper›PMID 38874764›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Total knee replacement with an accelerometer-based, hand-held navigation system improves knee alignment: reliable in all patients.

Diego Alarcon Perico, Sergio F Guarin Perez, Sheng-Hsun Lee, Christopher N Warne, Matthew Hadley, Michael J Taunton, Rafael J Sierra

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Diego Alarcon PericoDepartment of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
Sergio F Guarin PerezDepartment of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
Sheng-Hsun LeeDepartment of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
Christopher N WarneDepartment of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
Matthew HadleyDepartment of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
Michael J TauntonDepartment of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA.
Rafael J SierraDepartment of Orthopedic Surgery, Mayo Clinic, 200 First Street S.W, Rochester, MN, 55905, USA. sierra.rafael@mayo.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAchieving adequate alignment has traditionally been an important goal in total knee arthroplasty to achieve long-term implant survival. While accelerometer-based hand-held navigation systems (ABN) has been introduced as a way to achieve alignment, there is a limited body of evidence on its accuracy, especially in patients under 65 years with differing etiologies for knee arthritis. This study aimed to assess the precision of a specific ABN system in restoring the mechanical axis and report surgical variables and complications, with particular attention to younger patients.

methodsWe conducted a retrospective review of 310 primary TKA performed with ABN from May 2016 to February 2021. The mean patient age was 67.4 (SD 8.9) years, with 43% under 65 years and mean body mass index of 33.2 (SD 6.8). The average surgical time was 96.8 min (57-171) and the average follow-up was 3.3 years (1.9-6.7). Data regarding length of stay, pain, range of motion (ROM), complications, and reinterventions were collected from the institutional joint arthroplasty registry and the medical records. Preoperative mechanical axis measurements and postoperative radiological data, including mechanical axis, component alignment and mechanical alignment outliers were analyzed.

resultsThe mean preoperative mechanical axis was 175.4° (SD 7.6), with 248 knees (80%) in preoperative varus. The mean postoperative mechanical axis was 179.5° (SD 1.96) with 98% of knees falling within ± 3° of the neutral mechanical axis. Only 6 knees (2 varus, 4 valgus) fell outside the ± 3° range. And 3 knees (1 varus, 2 valgus) fell outside the ± 5° range. In the sagittal plane, 296 knees (95.5%) knees were within ± 3° of goal of 3 degrees of femoral flexion and 302 (97.4%) knees were within ± 2° of goal 1° of slope for tibial component. Far outliers (alignment outside ± 5° of targeted position) were found in 3 knees. Factors such as posttraumatic arthrosis, previous surgery, presence of retained hardware, and age below 65 years were not associated with increase in alignment outliers and far outliers. No complications related to the navigation system were observed. There were 22 complications and 20 reoperations, including 2 revisions for periprosthetic joint infection and 1 revision for flexion instability. Patients that required knee manipulation achieved an ultimate flexion of 110° (SD 14.1).

conclusionsThe ABN system proved to be user-friendly and accurate in reducing alignment outliers in both coronal and sagittal planes in all patient populations. It offers a straightforward navigation solution while preserving surgeon autonomy and the use of traditional surgical tools. These findings advocate for the integration of this navigation system as a valuable tool to enhance the precision of TKA surgery in all patient groups.

Indexed as

AccelerometryArthroplasty, Replacement, KneeAgedFemaleHumansKnee JointMaleMiddle AgedOsteoarthritis, KneeRange of Motion, ArticularRetrospective StudiesSurgical Navigation SystemsAccelerometer based navigationComplicationsKnee alignmentOrthAlignTotal knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked