ArticleArchives of orthopaedic and trauma surgery2024

The predictive value and reliability of ultrasound-guided synovial aspiration and biopsies for diagnosing periprosthetic shoulder infections.

N Pruijn, P J C Heesterbeek, S Susan, S S Boks, S C van Bokhoven, B W Schreurs, D Telgt, O Dorrestijn

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

N PruijnSint Maartenskliniek Research, Sint Maartenskliniek, P.O. Box 9011, Nijmegen, 6500 GM, the Netherlands. n.pruijn@maartenskliniek.nl.ORCID http://orcid.org/0000-0002-8967-7071
P J C HeesterbeekSint Maartenskliniek Research, Sint Maartenskliniek, P.O. Box 9011, Nijmegen, 6500 GM, the Netherlands.
S SusanSint Maartenskliniek Research, Sint Maartenskliniek, P.O. Box 9011, Nijmegen, 6500 GM, the Netherlands.
S S BoksDepartment of Radiology, Sint Maartenskliniek, Nijmegen, the Netherlands.
S C van BokhovenDepartment of Radiology, Sint Maartenskliniek, Nijmegen, the Netherlands.
B W SchreursDepartment of Orthopaedics, Radboud University Medical Center, Nijmegen, the Netherlands.
D TelgtInternist-infectiologist, Sint Maartenskliniek, Nijmegen, the Netherlands.
O DorrestijnDepartment of Orthopaedic Surgery, Sint Maartenskliniek, Nijmegen, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPreoperative diagnosis of periprosthetic shoulder infections (PSI) is difficult. Infections are mostly caused by low virulence bacteria and patients do not show typical signs of infection. The aim of this study was to determine the diagnostic value and reliability of ultrasound-guided biopsies for cultures alone and in combination with multiplex polymerase chain reaction (mPCR), serum markers, and/or synovial markers for the preoperative diagnosis of PSI in patients undergoing revision shoulder surgery. MATERIALS AND

methodsA prospective explorative diagnostic cohort study was performed including 55 patients undergoing revision shoulder replacement surgery. A shoulder puncture was performed preoperatively before incision to collect synovial fluid for mPCR analysis and for measurement of interleukin-6, calprotectin, white blood cell count (WBC), and polymorphonuclear cells. Also prior to revision surgery, six ultrasound-guided synovial tissue biopsies were collected for culture and two for mPCR analysis. A blood sample was obtained to determine serum C-reactive protein, WBC, and erythrocyte sedimentation rate. Six routine care tissue biopsies were taken during revision surgery and served as reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV; the primary outcome measure), and accuracy were calculated for ultrasound-guided biopsies, blood and synovial markers, mPCR, and combinations thereof.

resultsRoutine tissue cultures were positive for infection in 24 patients. Cultures from ultrasound-guided biopsies diagnosed infection in 7 of these patients, yielding a sensitivity, specificity, PPV, NPV, and accuracy of 29.2%, 93.5%, 77.8%, 63.0%, and 65.6%, respectively. The best diagnostic value was found for the combination of ultrasound-guided biopsies for culture, synovial WBC, and calprotectin with a sensitivity of 69.2%, specificity of 80.0%, PPV of 69.2%, and NPV of 80.0%.

conclusionUltrasound-guided biopsies for cultures alone and in combination with mPCR, and/or blood and/or synovial markers are not reliable enough to use in clinical practice for the preoperative diagnosis of PSI. LEVEL OF EVIDENCE: Diagnostic study level II.

Indexed as

Prosthesis-Related InfectionsAgedAged, 80 and overArthroplasty, Replacement, ShoulderBiomarkersFemaleHumansImage-Guided BiopsyMaleMiddle AgedPredictive Value of TestsProspective StudiesReoperationReproducibility of ResultsSensitivity and SpecificityShoulder JointBiomarkersCutibacterium acnesmPCRShoulder infectionSynovial markersUltrasound-guided biopsies