Evidence map›Paper›PMID 38869431›Full record

ArticleRadiology. Cardiothoracic imaging2024

MRI in Patients with Cardiovascular Implantable Electronic Devices and Fractured or Abandoned Leads.

Mark J Greenhill, Pooja Rangan, Wilber Su, J Peter Weiss, Michael Zawaneh, Samuel Unzek, Balaji Tamarappoo, Julia Indik, Roderick Tung, Michael F Morris

Erratum issuedAbstract read
In one paragraph

Article in Radiology. Cardiothoracic imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Cardiac implantable electronic device upgrades and downgrades: a Clinical Consensus Statement of the European Heart Rhythm Association (EHRA) of the ESC, the Asia Pacific Heart Rhythm Association (APHRS), Canadian Heart Rhythm Society (CHRS), Heart Rhythm Society (HRS), and the Latin American Heart Rhythm Society (LAHRS).Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Article
  4. Article
  5. Article
  6. Radiology. Cardiothoracic imaging · 2025
    Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors.

Mark J GreenhillFrom the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006.
Pooja RanganFrom the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006.ORCID 0000-0002-1801-5580
Wilber SuFrom the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006.ORCID 0000-0002-0639-6822
J Peter WeissFrom the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006.ORCID 0000-0002-1228-2581
Michael ZawanehFrom the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006.ORCID 0009-0000-8537-7701
Samuel UnzekFrom the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006.
Balaji TamarappooFrom the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006.ORCID 0000-0002-8382-4421
Julia IndikFrom the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006.ORCID 0000-0002-9279-4746
Roderick TungFrom the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006.ORCID 0000-0002-8513-1303
Michael F MorrisFrom the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006.ORCID 0000-0001-8076-0488

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or abandoned leads undergoing 1.5-T MRI. Materials and Methods This Health Insurance Portability and Accountability Act-compliant retrospective study included patients with CIEDs and abandoned leads or lead fragments undergoing 1.5-T MRI from March 2014 through July 2020. CIED settings before and after MRI were reviewed, with clinically significant variations defined as a composite of the change in capture threshold of at least 50%, in sensing of at least 40%, or in lead impedance of at least 30% between before MRI and after MRI interrogation. Adverse clinical events were assessed at MRI and up to 30 days after. Univariable and multivariable analysis was performed. Results Eighty patients with 126 abandoned CIED leads or lead fragments underwent 107 1.5-T MRI examinations. Sixty-seven patients (median age, 74 years; IQR, 66-78 years; 44 male patients, 23 female patients) had abandoned leads, and 13 (median age, 66 years; IQR, 52-74 years; nine male patients, four female patients) had lead fragments. There were no reported deaths, clinically significant arrhythmias, or adverse clinical events within 30 days of MRI. Three patients with abandoned leads had a significant change in the composite of capture threshold, sensing, or lead impedance. In a multivariable generalized estimating equation analysis, lead orientation, lead length, MRI type, and MRI duration were not associated with a significant change in the composite outcome. Conclusion Use of 1.5-T MRI in patients with abandoned CIED leads or lead fragments of varying length and orientation was not associated with adverse clinical events.

Indexed as

Defibrillators, ImplantableEquipment FailureMagnetic Resonance ImagingPacemaker, ArtificialAgedFemaleHumansMaleMiddle AgedRetrospective StudiesCardiac Assist DevicesCardiac Implantable Electronic DeviceMRI

Identifiers

PMID38869431
PMCPMC11211945

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.