Evidence map›Paper›PMID 38867799›Full record

ArticleBiomedical optics express2024

Fluorescence saturation imaging microscopy: molecular fingerprinting with a standard confocal microscope.

Boris Yakimov, Natalia Rovnyagina, Afraa Hasan, Juntao Zhang, Haibo Wang, Victor Fadeev, Liliya Urusova, Evgeny Khoroshilov, Andrey Sharkov, Nataliya Mokrysheva and 1 more

Abstract read
In one paragraph

Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Boris YakimovLaboratory of Clinical Biophotonics, Sechenov First Moscow State Medical University, Trubetskaya 8, Moscow 119048, Russia.
Natalia RovnyaginaLaboratory of Clinical Biophotonics, Sechenov First Moscow State Medical University, Trubetskaya 8, Moscow 119048, Russia.
Afraa HasanHSE University, Faculty of Physics, Myasnitskaya St., 20, Moscow 101100, Russia.
Juntao ZhangSchool of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, Hubei 4300023, China.
Haibo WangSchool of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, Hubei 4300023, China.
Victor FadeevFaculty of Physics, M.V. Lomonosov Moscow State University, 1-2 Leninskie Gory, 119991 Moscow, Russia.
Liliya UrusovaEndocrinology Research Center, Dmitriya Ulianova Street, 11, 117036 Moscow, Russia.
Evgeny KhoroshilovP.N. Lebedev Physical Institute, Russian Academy of Sciences, 53 Leninsky Pr., 119991 Moscow, Russia.
Andrey SharkovP.N. Lebedev Physical Institute, Russian Academy of Sciences, 53 Leninsky Pr., 119991 Moscow, Russia.
Nataliya MokryshevaEndocrinology Research Center, Dmitriya Ulianova Street, 11, 117036 Moscow, Russia.
Evgeny ShirshinFaculty of Physics, M.V. Lomonosov Moscow State University, 1-2 Leninskie Gory, 119991 Moscow, Russia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Molecular specificity in fluorescence imaging of cells and tissues can be increased by measuring parameters other than intensity. For instance, fluorescence lifetime imaging became a widespread modality for biomedical optics. Previously, we suggested using the fluorescence saturation effect at pulsed laser excitation to map the absorption cross-section as an additional molecular contrast in two-photon microscopy [Opt. Lett.47(17), 4455 (2022).10.1364/OL.465605]. Here, it is shown that, somewhat counterintuitive, fluorescence saturation can be observed under cw excitation in a standard confocal microscopy setup. Mapping the fluorescence saturation parameter allows obtaining additional information about the fluorophores in the system, as demonstrated by the example of peptide hydrogel, stained cells and unstained thyroid gland. The suggested technique does not require additional equipment and can be implemented on confocal systems as is.

Identifiers

PMID38867799
PMCPMC11166444

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.