ArticleThe journal of pediatric pharmacology and therapeutics : JPPT : the official journal of PPAG2024
Impact of Extracorporeal Membrane Oxygenation Circuitry on Remdesivir.
Article in The journal of pediatric pharmacology and therapeutics : JPPT : the official journal of PPAG, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThis study aimed to determine the oxygenator impact on alterations of remdesivir (RDV) in a contemporary neonatal/pediatric (1/4-inch) and adolescent/adult (3/8-inch) extracorporeal membrane -oxygenation (ECMO) circuit including the Quadrox-i oxygenator.
methodsOne-quarter-inch and a 3/8-inch, simulated closed-loop ECMO circuits were prepared with a Quadrox-i pediatric and Quadrox-i adult oxygenator and blood primed. Additionally, 1/4-inch and 3/8-inch circuits were also prepared without an oxygenator in series. A 1-time dose of RDV was administered into the circuits and serial preoxygenator and postoxygenator concentrations were obtained at 0 to 5 minutes, and 1-, 2-, 3-, 4-, 5-, 6-, 8-, 12-, and 24-hour time points. The RDV was also maintained in a glass vial and samples were taken from the vial at the same time periods for control purposes to assess for spontaneous drug degradation.
resultsFor the 1/4-inch circuits with an oxygenator, there was a 35% to 60% RDV loss during the study period. For the 1/4-inch circuits without an oxygenator, there was a 5% to 20% RDV loss during the study period. For the 3/8-inch circuit with and without an oxygenator, there was a 60% to 70% RDV loss during the study period.
conclusionsThere was RDV loss within the circuit during the study period and the RDV loss was more pronounced with the larger 3/8-inch circuit when compared with the 1/4-inch circuit. The impact of the -oxygenator on RDV loss appears to be variable and possibly dependent on the size of the circuit and -oxygenator. These preliminary data suggest RDV dosing may need to be adjusted for concern of drug loss via the ECMO circuit. Additional single- and multiple-dose studies are needed to validate these findings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.