Comparison of the Kron technique and digital manometry for measuring intra-abdominal pressure in emergency department patients diagnosed with ileus.

Merve Unutmaz, Çağdaş Yıldırım, Mehmet Emin Unutmaz, Gül Pamukçu Günaydın, Alp Şener, Şervan Gökhan

Abstract readComparative Study
In one paragraph

Article in Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Merve UnutmazDepartment of Emergency Medicine, Ankara Bilkent City Hospital, Ankara-Türkiye.
Çağdaş YıldırımDepartment of Emergency Medicine, Ankara Yıldırım Beyazıt University, School of Medicine, Ankara-Türkiye.
Mehmet Emin UnutmazDepartment of Oncologic Surgery, Ankara Etlik City Hospital, Ankara-Türkiye.
Gül Pamukçu GünaydınDepartment of Emergency Medicine, Ankara Yıldırım Beyazıt University, School of Medicine, Ankara-Türkiye.
Alp ŞenerDepartment of Emergency Medicine, Ankara Yıldırım Beyazıt University, School of Medicine, Ankara-Türkiye.
Şervan GökhanDepartment of Emergency Medicine, Ankara Yıldırım Beyazıt University, School of Medicine, Ankara-Türkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNumerous measurement techniques for intra-abdominal pressure have been explored, with the Kron Technique established as the gold standard. Despite its prominence, the search for alternative methods persists due to its lengthy application time, the requirement for additional equipment, and overall impracticality. This study investigated a quicker, more accessible method for effective intra-abdominal pressure measurement in the emergency department. It aimed to compare intra-abdominal pressure measurements in patients diagnosed with ileus using a digital manometer and the Kron Technique.

methodsConducted from October 2022 to February 2023, this single-center, prospective, single-blind method comparison study involved patients diagnosed with ileus at a tertiary emergency department. Intra-abdominal pressure was measured using both the Kron Technique and a digital manometer by separate practitioners blinded to the study results.

resultsThe study included 30 patients. No statistically significant difference was observed in the intra-abdominal pressure measurements between the two methods (p<0.237). A very strong correlation existed between the two methods (Spearman's Rho = 0.998). Bland-Altman analysis showed a bias value of 0.091 mmHg for the digital manometer, with upper and lower agreement limits of -0.825 and 1.007 mmHg, respectively. The measurement time was significantly shorter with the digital manometer than with the Kron Technique (15 vs. 390.5 seconds; p<0.001).

conclusionWe believe that the intra-abdominal pressure measurement technique using a digital manometer is a method that can be effectively employed by healthcare professionals in emergency departments. This technique offers ease of use, requires minimal equipment, provides rapid results, and delivers reliable measurement values compared to the Kron Technique.

Indexed as

Emergency Service, HospitalIleusManometryPressureAdultAgedAged, 80 and overFemaleHumansMaleMiddle AgedProspective StudiesSingle-Blind Method

Identifiers

PMID38863287
PMCPMC11230050

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.