Evidence map›Paper›PMID 38863180›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2024

Enhanced Sweat Biosensing with Thread-Embedded Microfluidic Devices.

Karunan Joseph, Fatimah Ibrahim, Saima Qureshi, Bojan Petrović, Sanja Kojić, Aung Thiha, Nurul Jamaluddin, Nuraina Dahlan, Goran Stojanović

Abstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Karunan JosephDepartment of Biomedical Engineering and Centre for Innovation in Medical Engineering (CIME), Universiti Malaya, Kuala Lumpur, Malaysia.
Fatimah IbrahimDepartment of Biomedical Engineering and Centre for Innovation in Medical Engineering (CIME), Universiti Malaya, Kuala Lumpur, Malaysia.
Saima QureshiFaculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia.
Bojan PetrovićFaculty of Medicine, University of Novi Sad, Novi Sad, Serbia.
Sanja KojićFaculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia.
Aung ThihaDepartment of Biomedical Engineering and Centre for Innovation in Medical Engineering (CIME), Universiti Malaya, Kuala Lumpur, Malaysia.
Nurul JamaluddinDepartment of Biomedical Engineering and Centre for Innovation in Medical Engineering (CIME), Universiti Malaya, Kuala Lumpur, Malaysia.
Nuraina DahlanDepartment of Biomedical Engineering and Centre for Innovation in Medical Engineering (CIME), Universiti Malaya, Kuala Lumpur, Malaysia.
Goran StojanovićFaculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND This study explored the integration of conductive threads into a microfluidic compact disc (CD), developed using the xurographic method, for a potential sweat biosensing platform. MATERIAL AND METHODS The microfluidic CD platform, fabricated using the xurographic method with PVC films, included venting channels and conductive threads linked to copper electrodes. With distinct microfluidic sets for load and metering, flow control, and measurement, the CD's operation involved spinning for sequential liquid movement. Impedance analysis using HIOKI IM3590 was conducted for saline and artificial sweat solutions on 4 identical CDs, ensuring reliable conductivity and measurements over a 1 kHz to 200 kHz frequency range. RESULTS Significant differences in |Z| values were observed between saline and artificial sweat treatments. 27.5 μL of saline differed significantly from 27.5 μL of artificial sweat, 72.5 μL of saline from 72.5 μL of artificial sweat, and 192.5 μL of saline from 192.5 μL of sweat. Significant disparities in |Z| values were observed between dry fibers and Groups 2, 3, and 4 (varying saline amounts). No significant differences emerged between dry fibers and Groups 6, 7, and 8 (distinct artificial sweat amounts). These findings underscore variations in fiber characteristics between equivalent exposures, emphasizing the nuanced response of the microfluidic CD platform to different liquid compositions. CONCLUSIONS This study shows the potential of integrating conductive threads in a microfluidic CD platform for sweat sensing. Challenges in volume control and thread coating degradation must be addressed for transformative biosensing devices in personalized healthcare.

Indexed as

Biosensing TechniquesLab-On-A-Chip DevicesSweatElectric ConductivityElectric ImpedanceElectrodesHumansMicrofluidics

Identifiers

PMID38863180
PMCPMC11181877

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.