Evidence map›Paper›PMID 38858832›Full record

ArticleMedical decision making : an international journal of the Society for Medical Decision Making2024

Emulator-Based Bayesian Calibration of the CISNET Colorectal Cancer Models.

Carlos Pineda-Antunez, Claudia Seguin, Luuk A van Duuren, Amy B Knudsen, Barak Davidi, Pedro Nascimento de Lima, Carolyn Rutter, Karen M Kuntz, Iris Lansdorp-Vogelaar, Nicholson Collier and 2 more

Abstract read
In one paragraph

Article in Medical decision making : an international journal of the Society for Medical Decision Making, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. A Metamodel-Based General-Purpose Autocalibration Tool for Simulation Models.Medical decision making : an international journal of the Society for Medical Decision Making · 2026
    Article
  2. Review
  3. Article
  4. Article
  5. A Scoping Review on Calibration Methods for Cancer Simulation Models.Medical decision making : an international journal of the Society for Medical Decision Making · 2025
    Article
  6. Evaluating Semi-Markov Processes and Other Epidemiological Time-to-Event Models by Computing Disease Sojourn Density as Partial Differential Equations.Medical decision making : an international journal of the Society for Medical Decision Making · 2025
    Article
  7. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

12 authors.

Carlos Pineda-AntunezThe Comparative Health Outcomes, Policy, and Economics (CHOICE) Institute, University of Washington, Seattle, WA, USA.ORCID 0000-0002-8352-7080
Claudia SeguinInstitute for Technology Assessment, Massachusetts General Hospital, Boston, MA, USA.
Luuk A van DuurenDepartment of Public Health, Erasmus MC Medical Center, Rotterdam, The Netherlands.
Amy B KnudsenInstitute for Technology Assessment, Massachusetts General Hospital, Boston, MA, USA.
Barak DavidiInstitute for Technology Assessment, Massachusetts General Hospital, Boston, MA, USA.
Pedro Nascimento de LimaRAND Corporation, Arlington, VA, USA.ORCID 0000-0001-9057-198X
Carolyn RutterFred Hutchinson Cancer Research Center, Hutchinson Institute for Cancer Outcomes Research, Biostatistics Program, Public Health Sciences Division, Seattle, WA, USA.
Karen M KuntzDivision of Health Policy & Management, University of Minnesota School of Public Health, Minneapolis, MN, USA.
Iris Lansdorp-VogelaarDepartment of Public Health, Erasmus MC Medical Center, Rotterdam, The Netherlands.
Nicholson CollierDecision and Infrastructure Sciences Division, Argonne National Laboratory, Lemont, IL, USA.
Jonathan OzikDecision and Infrastructure Sciences Division, Argonne National Laboratory, Lemont, IL, USA.
Fernando Alarid-EscuderoDepartment of Health Policy, School of Medicine, Stanford University, CA, USA.ORCID 0000-0001-5076-1172

Funding

Comparative Modeling of Effective Policies for Colorectal Cancer ControlU01CA253913 · NCI · SLOAN-KETTERING INST CAN RESEARCH · PI RUTTER, CAROLYN M, ZAUBER, ANN GRAHAM · 2020 to 2025
$6.5M
NCI NIH HHS U01 CA253913US Department of Energy DE-AC0206CH11357
6 · The paper itself

Abstract

purposeTo calibrate Cancer Intervention and Surveillance Modeling Network (CISNET)'s SimCRC, MISCAN-Colon, and CRC-SPIN simulation models of the natural history colorectal cancer (CRC) with an emulator-based Bayesian algorithm and internally validate the model-predicted outcomes to calibration targets.

methodsWe used Latin hypercube sampling to sample up to 50,000 parameter sets for each CISNET-CRC model and generated the corresponding outputs. We trained multilayer perceptron artificial neural networks (ANNs) as emulators using the input and output samples for each CISNET-CRC model. We selected ANN structures with corresponding hyperparameters (i.e., number of hidden layers, nodes, activation functions, epochs, and optimizer) that minimize the predicted mean square error on the validation sample. We implemented the ANN emulators in a probabilistic programming language and calibrated the input parameters with Hamiltonian Monte Carlo-based algorithms to obtain the joint posterior distributions of the CISNET-CRC models' parameters. We internally validated each calibrated emulator by comparing the model-predicted posterior outputs against the calibration targets.

resultsThe optimal ANN for SimCRC had 4 hidden layers and 360 hidden nodes, MISCAN-Colon had 4 hidden layers and 114 hidden nodes, and CRC-SPIN had 1 hidden layer and 140 hidden nodes. The total time for training and calibrating the emulators was 7.3, 4.0, and 0.66 h for SimCRC, MISCAN-Colon, and CRC-SPIN, respectively. The mean of the model-predicted outputs fell within the 95% confidence intervals of the calibration targets in 98 of 110 for SimCRC, 65 of 93 for MISCAN, and 31 of 41 targets for CRC-SPIN.

conclusionsUsing ANN emulators is a practical solution to reduce the computational burden and complexity for Bayesian calibration of individual-level simulation models used for policy analysis, such as the CISNET CRC models. In this work, we present a step-by-step guide to constructing emulators for calibrating 3 realistic CRC individual-level models using a Bayesian approach. HIGHLIGHTS: We use artificial neural networks (ANNs) to build emulators that surrogate complex individual-based models to reduce the computational burden in the Bayesian calibration process.ANNs showed good performance in emulating the CISNET-CRC microsimulation models, despite having many input parameters and outputs.Using ANN emulators is a practical solution to reduce the computational burden and complexity for Bayesian calibration of individual-level simulation models used for policy analysis.This work aims to support health decision scientists who want to quantify the uncertainty of calibrated parameters of computationally intensive simulation models under a Bayesian framework.

Indexed as

AlgorithmsBayes TheoremColorectal NeoplasmsNeural Networks, ComputerCalibrationComputer SimulationHumansMonte Carlo Methodartificial neural networksBayesian calibrationcolorectal cancer modelemulatormachine learning

Identifiers

PMID38858832
PMCPMC11281870

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.