Evidence map›Paper›PMID 38856876›Full record

ArticleInternational journal of implant dentistry2024

Round and flat zygomatic implants: effectiveness after a 3‑year follow‑up non‑interventional study.

Carlos Aparicio, Waldemar D Polido, Antoine Chehade, Marc Shenouda, Madalina Simon, Peter Simon, Bilal Al-Nawas

Abstract read
In one paragraph

Article in International journal of implant dentistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Carlos AparicioZygomatic Unit, Hepler Bone Clinic, ZAGA Center Barcelona, Roman Macaya, 22-24, 08022, Barcelona, Spain. carlos.aparicio@zagacenters.com.ORCID 0000-0002-2069-691X
Waldemar D PolidoOral and Maxillofacial Surgery, Indiana University School of Dentistry Indianapolis, USA. ZAGA Center, Indiana University, 1121 W. Michigan Street, Indianapolis, IN, 46202, USA.
Antoine ChehadeSeaforth Oral Surgery, ZAGA Center Montreal, 3550 côte des neiges, suite 170, Montreal, QC, H3H 1V4, Canada.
Marc ShenoudaSeaforth Oral Surgery, ZAGA Center Montreal, 3550 côte des neiges, suite 170, Montreal, QC, H3H 1V4, Canada.
Madalina SimonZAGA Center Stuttgart, All-On-4 Excellence Center, Kronprinzstraße 11, 70173, Stuttgart, Germany.
Peter SimonZAGA Center Stuttgart, All-On-4 Excellence Center, Kronprinzstraße 11, 70173, Stuttgart, Germany.
Bilal Al-NawasDepartment for Oral and Maxillofacial Surgery, Plastic Surgery, University Medical Center of the J. Gutenberg University Mainz, Augustusplatz 2, 55131, Mainz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis non-interventional study investigates variations in the type and frequency of late complications linked to novel zygomatic implant designs, installed adhering to the Zygoma Anatomy-Guided Approach (ZAGA) concept, over an extended follow-up period of at least 3 years.

methodsConsecutive patients presenting indications for treatment with ZIs were treated according to ZAGA recommendations. Implants were immediately loaded. The ORIS success criteria for prosthetic offset, stability, sinus changes and soft-tissue status were used to evaluate the outcome.

resultsTwenty patients were treated. Ten patients received two ZIs and regular implants; one received three ZIs plus regular implants, and nine received four ZIs. Fifty-nine ZIs were placed: thirty-six (61%) Straumann ZAGA-Flat implants and twenty-three (39%) Straumann ZAGA-Round implants. Four patients (20%) presented earlier sinus floor discontinuities. Fifteen patients (75%) had prior sinus opacities. Nineteen patients were followed for between 38 and 53 months (mean 46.5 months). One patient dropped out after 20 months. When comparing pre-surgical CBCT with post-surgical CBCT, 84.7% of the sites presented identical or less sinus opacity; nine locations (15%) showed decreased, and another nine increased (15%) post-surgical sinus opacity. Fifty-three ZIs (89.8%) maintained stable soft tissue. Six ZIs had recessions with no signs of infection. ZIs and prosthesis survival rate was 100%.

conclusionsThe study highlights the effectiveness of ZAGA-based zygomatic implant rehabilitations using Round and Flat designs. Despite patient number constraints, minimal changes in the frequency of late complications from the 1-year follow-up were observed. 100% implant and prosthesis survival rate over a mean follow-up of 46.5 months is reported.

Indexed as

Dental ImplantsZygomaAdultAgedDental Prosthesis DesignFemaleFollow-Up StudiesHumansMaleMiddle AgedTreatment OutcomeDental ImplantsORIS criteriaZAGAZAGA-flatZAGA implantsZAGA-roundZygomatic implant late complicationsZygomatic implants

Identifiers

PMID38856876
PMCPMC11164844

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.