Evidence map›Paper›PMID 38856781›Full record

ArticleEuropean radiology2024

In vitro blood sample assessment: investigating correlation of laboratory hemoglobin and spectral properties of dual-energy CT measurements (ρ/Z).

Bastian Schulz, André Euler, Hans-Ruedi Schmid, Rahel A Kubik-Huch, Michael Thali, Tilo Niemann

Abstract read
In one paragraph

Article in European radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Bastian SchulzInstitute of Radiology, Kantonsspital Baden AG, affiliated Hospital for Research and Teaching of the Faculty of Medicine of the University of Zurich, Baden, Switzerland.ORCID http://orcid.org/0009-0000-6546-0276
André EulerInstitute of Radiology, Kantonsspital Baden AG, affiliated Hospital for Research and Teaching of the Faculty of Medicine of the University of Zurich, Baden, Switzerland.ORCID http://orcid.org/0000-0001-5019-4585
Hans-Ruedi SchmidCentral Laboratory, Kantonsspital Baden AG, Baden, Switzerland.ORCID http://orcid.org/0000-0002-5517-330X
Rahel A Kubik-HuchInstitute of Radiology, Kantonsspital Baden AG, affiliated Hospital for Research and Teaching of the Faculty of Medicine of the University of Zurich, Baden, Switzerland.ORCID http://orcid.org/0000-0002-3636-8697
Michael ThaliDepartment of Forensic Medicine Zurich, University of Zurich, Zurich, Switzerland.ORCID http://orcid.org/0000-0002-2613-6956
Tilo NiemannInstitute of Radiology, Kantonsspital Baden AG, affiliated Hospital for Research and Teaching of the Faculty of Medicine of the University of Zurich, Baden, Switzerland. tilo.niemann@ksb.ch.ORCID http://orcid.org/0000-0002-5384-2522

Funding

Guerbet AG, Switzerland N/A
6 · The paper itself

Abstract

objectivesOur study comprised a single-center retrospective in vitro correlation between spectral properties, namely ρ/Z values, derived from scanning blood samples using dual-energy computed tomography (DECT) with the corresponding laboratory hemoglobin/hematocrit (Hb/Hct) levels and assessed the potential in anemia-detection.

methodsDECT of 813 patient blood samples from 465 women and 348 men was conducted using a standardized scan protocol. Electron density relative to water (ρ or rho), effective atomic number (Z

resultsPositive correlation with the Hb/Hct was shown for ρ (r-values 0.37-0.49) and attenuation (r-values 0.59-0.83) while no correlation was observed for Z

conclusionIn summary, our study investigated the correlation between DECT measurements and Hb/Hct levels, emphasizing novel aspects of ρ and Z CLINICAL RELEVANCE STATEMENT: By scanning multiple blood samples with dual-energy CT scans and comparing the measurements with standard laboratory blood tests, we were able to underscore the potential of CT-based anemia detection and its advantages in clinical practice. KEY POINTS: Prior in vivo studies have found a correlation between aortic blood pool and measured hemoglobin and hematocrit. Hemoglobin and hematocrit correlated with electron density relative to water and attenuation but not Z

Indexed as

AnemiaHemoglobinsTomography, X-Ray ComputedAdultAgedAged, 80 and overFemaleHematocritHumansIn Vitro TechniquesMaleMiddle AgedRadiography, Dual-Energy Scanned ProjectionRetrospective StudiesHemoglobinsAnemiaBloodComputer-assisted radiographic image interpretationDual-energy computed tomographyX-ray computed tomography scanners

Identifiers

PMID38856781
PMCPMC11557693

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.