Evidence map›Paper›PMID 38855668›Full record

ArticleBiomedical optics express2024

Megahertz multi-parametric ophthalmic OCT system for whole eye imaging.

Yicheng Hu, Yutao Feng, Xing Long, Dongye Zheng, Gangjun Liu, Yanye Lu, Qiushi Ren, Zhiyu Huang

Abstract read
In one paragraph

Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Closing the Loop: High-Precision 3D Photofabrication in Living Tissues.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yicheng HuDepartment of Biomedical Engineering, College of Future Technology, Peking University, Beijing 100871, China.ORCID https://orcid.org/0009-0003-4350-4006
Yutao FengDepartment of Biomedical Engineering, College of Future Technology, Peking University, Beijing 100871, China.
Xing LongDepartment of Biomedical Engineering, College of Future Technology, Peking University, Beijing 100871, China.
Dongye ZhengDepartment of Biomedical Engineering, College of Future Technology, Peking University, Beijing 100871, China.
Gangjun LiuInstitute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen 518071, China.
Yanye LuInstitute of Biomedical Engineering, Peking University Shenzhen Graduate School, Shenzhen 518055, China.ORCID https://orcid.org/0000-0002-3063-8051
Qiushi RenDepartment of Biomedical Engineering, College of Future Technology, Peking University, Beijing 100871, China.
Zhiyu HuangInstitute of Biomedical Engineering, Peking University Shenzhen Graduate School, Shenzhen 518055, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An ultrahigh-speed, wide-field OCT system for the imaging of anterior, posterior, and ocular biometers is crucial for obtaining comprehensive ocular parameters and quantifying ocular pathology size. Here, we demonstrate a multi-parametric ophthalmic OCT system with a speed of up to 1 MHz for wide-field imaging of the retina and 50 kHz for anterior chamber and ocular biometric measurement. A spectrum correction algorithm is proposed to ensure the accurate pairing of adjacent A-lines and elevate the A-scan speed from 500 kHz to 1 MHz for retinal imaging. A registration method employing position feedback signals was introduced, reducing pixel offsets between forward and reverse galvanometer scanning by 2.3 times. Experimental validation on glass sheets and the human eye confirms feasibility and efficacy. Meanwhile, we propose a revised formula to determine the "true" fundus size using all-axial length parameters from different fields of view. The efficient algorithms and compact design enhance system compatibility with clinical requirements, showing promise for widespread commercialization.

Identifiers

PMID38855668
PMCPMC11161356

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.