Evidence map›Paper›PMID 38854889›Full record

ArticleBJR case reports2024

Implications of lung shunt fraction calculation discrepancy in Yttrium-90 radioembolization treatment from 2D planar vs 3D single photon emission CT imaging.

Paula Gamero Kubota, Christopher Molvar, Robert Wagner, Emad Allam, James Halama, Judy R James

Abstract readCase Reports
In one paragraph

Article in BJR case reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Paula Gamero KubotaDepartment of Radiology and Medical Imaging, Loyola University School of Medicine, Maywood, IL60153, United States.ORCID https://orcid.org/0000-0003-1167-015X
Christopher MolvarDepartment of Radiology and Medical Imaging, Loyola University School of Medicine, Maywood, IL60153, United States.
Robert WagnerDepartment of Radiology and Medical Imaging, Loyola University School of Medicine, Maywood, IL60153, United States.
Emad AllamDepartment of Radiology and Medical Imaging, Loyola University School of Medicine, Maywood, IL60153, United States.
James HalamaDepartment of Radiology and Medical Imaging, Loyola University School of Medicine, Maywood, IL60153, United States.
Judy R JamesDepartment of Radiology and Medical Imaging, Loyola University School of Medicine, Maywood, IL60153, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The safety and efficacy of Yttrium-90 (Y-90) radio-embolization therapy is partly dependent on the lung shunt fraction (LSF). There may be a notable disparity between LSF when calculated using 2D planar imaging vs 3D single photon emission CT (SPECT); this can affect the total allowable Y-90 dose delivered and therefore change the effectiveness of the procedure. The case presented demonstrates an 81% decrease in LSF when calculated by SPECT as compared to 2D planar imaging. This case highlights the importance of considering the imaging technique and the potential discrepancies that can arise between planar and SPECT imaging in LSF assessment.

Indexed as

hepatocellular carcinomalung shunt fractionplanar imagingsingle photon emission CT (SPECT)trans-arterial radioembolizationY-90

Identifiers

PMID38854889
PMCPMC11162746

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.