Evidence map›Paper›PMID 38853221›Full record

SynthesisBreast cancer research and treatment2024

Frequency and characteristics of errors by artificial intelligence (AI) in reading screening mammography: a systematic review.

Aileen Zeng, Nehmat Houssami, Naomi Noguchi, Brooke Nickel, M Luke Marinovich

Abstract readSystematic ReviewMeta-Analysis
In one paragraph

Synthesis in Breast cancer research and treatment, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. Review
  16. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Aileen ZengThe Daffodil Centre, The University of Sydney, a Joint Venture with Cancer Council New South Wales, Sydney, NSW, Australia.ORCID http://orcid.org/0000-0002-7528-8630
Nehmat HoussamiThe Daffodil Centre, The University of Sydney, a Joint Venture with Cancer Council New South Wales, Sydney, NSW, Australia.ORCID http://orcid.org/0000-0002-3641-952X
Naomi NoguchiSchool of Public Health, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia.ORCID http://orcid.org/0000-0001-5662-1496
Brooke NickelWiser Healthcare, Sydney School of Public Health, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia.ORCID http://orcid.org/0000-0002-8100-4278
M Luke MarinovichThe Daffodil Centre, The University of Sydney, a Joint Venture with Cancer Council New South Wales, Sydney, NSW, Australia. luke.marinovich@sydney.edu.au.ORCID http://orcid.org/0000-0002-3801-8180

Funding

National Breast Cancer Foundation 2023/IIRS0028National Breast Cancer Foundation EC-21-001National Health and Medical Research Council 1194108National Health and Medical Research Council 1194410The Daffodil Centre Postgraduate Research Scholarship
6 · The paper itself

Abstract

purposeArtificial intelligence (AI) for reading breast screening mammograms could potentially replace (some) human-reading and improve screening effectiveness. This systematic review aims to identify and quantify the types of AI errors to better understand the consequences of implementing this technology.

methodsElectronic databases were searched for external validation studies of the accuracy of AI algorithms in real-world screening mammograms. Descriptive synthesis was performed on error types and frequency. False negative proportions (FNP) and false positive proportions (FPP) were pooled within AI positivity thresholds using random-effects meta-analysis.

resultsSeven retrospective studies (447,676 examinations; published 2019-2022) met inclusion criteria. Five studies reported AI error as false negatives or false positives. Pooled FPP decreased incrementally with increasing positivity threshold (71.83% [95% CI 69.67, 73.90] at Transpara 3 to 10.77% [95% CI 8.34, 13.79] at Transpara 9). Pooled FNP increased incrementally from 0.02% [95% CI 0.01, 0.03] (Transpara 3) to 0.12% [95% CI 0.06, 0.26] (Transpara 9), consistent with a trade-off with FPP. Heterogeneity within thresholds reflected algorithm version and completeness of the reference standard. Other forms of AI error were reported rarely (location error and technical error in one study each).

conclusionAI errors are largely interpreted in the framework of test accuracy. FP and FN errors show expected variability not only by positivity threshold, but also by algorithm version and study quality. Reporting of other forms of AI errors is sparse, despite their potential implications for adoption of the technology. Considering broader types of AI error would add nuance to reporting that can inform inferences about AI's utility.

Indexed as

Artificial IntelligenceBreast NeoplasmsMammographyAlgorithmsDiagnostic ErrorsEarly Detection of CancerFalse Negative ReactionsFalse Positive ReactionsFemaleHumansArtificial intelligenceBreast cancerDiagnostic errorsPopulation screening

Identifiers

PMID38853221
PMCPMC11230971

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.