Evidence map›Paper›PMID 38848033›Full record

ArticleInternational journal of computer assisted radiology and surgery2025

Simulation of thoracic endovascular aortic repair in a perfused patient-specific model of type B aortic dissection.

Lukas Mohl, Roger Karl, Matthias N Hagedorn, Armin Runz, Stephan Skornitzke, Malte Toelle, C Soeren Bergt, Johannes Hatzl, Christian Uhl, Dittmar Böckler and 2 more

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. 3D-printed in vitro models of Stanford type B aortic dissection: A scoping review.Journal of vascular surgery cases and innovative techniques · 2025
    Article
  4. Review
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Lukas Mohl *Department of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany. l.mohl@stud.uni-heidelberg.de.ORCID http://orcid.org/0009-0005-7153-1073
Roger Karl *Department of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.ORCID http://orcid.org/0000-0003-4732-8495
Matthias N HagedornDepartment of Vascular Surgery and Endovascular Surgery, University Hospital Heidelberg, Heidelberg, Germany.ORCID http://orcid.org/0000-0002-5477-6731
Armin RunzDKFZ, German Cancer Research Center, Heidelberg, Germany.
Stephan SkornitzkeDiagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg, Germany.
Malte ToelleDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.ORCID http://orcid.org/0000-0002-0804-5794
C Soeren BergtDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.ORCID http://orcid.org/0009-0008-1592-3277
Johannes HatzlDepartment of Vascular Surgery and Endovascular Surgery, University Hospital Heidelberg, Heidelberg, Germany.ORCID http://orcid.org/0000-0002-3152-7791
Christian UhlDepartment of Vascular Surgery and Endovascular Surgery, University Hospital Heidelberg, Heidelberg, Germany.
Dittmar BöcklerDepartment of Vascular Surgery and Endovascular Surgery, University Hospital Heidelberg, Heidelberg, Germany.
Katrin MeisenbacherDepartment of Vascular Surgery and Endovascular Surgery, University Hospital Heidelberg, Heidelberg, Germany.
Sandy EngelhardtDepartment of Cardiac Surgery, Heidelberg University Hospital, Heidelberg, Germany.ORCID http://orcid.org/0000-0001-8816-7654

Funding

Heidelberger Stiftung Chirurgie 2023/606
6 · The paper itself

Abstract

purposeComplicated type B Aortic dissection is a severe aortic pathology that requires treatment through thoracic endovascular aortic repair (TEVAR). During TEVAR a stentgraft is deployed in the aortic lumen in order to restore blood flow. Due to the complicated pathology including an entry, a resulting dissection wall with potentially several re-entries, replicating this structure artificially has proven to be challenging thus far.

methodsWe developed a 3d printed, patient-specific and perfused aortic dissection phantom with a flexible dissection flap and all major branching vessels. The model was segmented from CTA images and fabricated out of a flexible material to mimic aortic wall tissue. It was placed in a pulsatile hemodynamic flow loop. Hemodynamics were investigated through pressure and flow measurements and doppler ultrasound imaging. Surgeons performed a TEVAR intervention including stentgraft deployment under fluoroscopic guidance.

resultsThe flexible aortic dissection phantom was successfully incorporated in the hemodynamic flow loop, a systolic pressure of 112 mmHg and physiological flow of 4.05 L per minute was reached. Flow velocities were higher in true lumen with a up to 35.7 cm/s compared to the false lumen with a maximum of 13.3 cm/s, chaotic flow patterns were observed on main entry and reentry sights. A TEVAR procedure was successfully performed under fluoroscopy. The position of the stentgraft was confirmed using CTA imaging.

conclusionsThis perfused in-vitro phantom allows for detailed investigation of the complex inner hemodynamics of aortic dissections on a patient-specific level and enables the simulation of TEVAR procedures in a real endovascular operating environment. Therefore, it could provide a dynamic platform for future surgical training and research.

Indexed as

Aorta, ThoracicAortic Aneurysm, ThoracicAortic DissectionEndovascular ProceduresPatient-Specific ModelingBlood Vessel Prosthesis ImplantationComputed Tomography AngiographyEndovascular Aneurysm RepairHemodynamicsHumansPhantoms, ImagingPrinting, Three-DimensionalStents3d printingAortic dissectionHemodynamic aortic flow loopIn vitro phantomPatient-specific aortaTEVAR simulation

Identifiers

PMID38848033
PMCPMC11807923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.