ArticleEndoscopy international open2024
Single-center experience with intraprocedural cleansing system to improve inadequate bowel preparation during colonoscopy.
Article in Endoscopy international open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Optimizing detection and resection of colorectal polyps.Translational gastroenterology and hepatology · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Inadequate bowel preparation is common despite various preprocedure interventions. There is a need for an intervention at the time of colonoscopy to combat poor preparation. In this retrospective, observational study of 46 patients, we evaluated the clinical efficacy and feasibility of implementing the third generation of the Pure-Vu EVS System, a US Food and Drug Administration-cleared over-the-scope-based intraprocedural cleansing device, into our practice at the Minneapolis VA Medical Center (Minneapolis, Minnesota, United States). To study clinical efficacy, we measured bowel preparation adequacy before and after using the device, as measured by the Boston Bowel Preparation Score, and reviewed colonoscopy surveillance interval recommendations. Technical success and feasibility of using the device were measured by procedure success rates and duration. We found that BBPS scores increased from 4.4 to 7.9 when using the device. Technical success was achieved 78.3% of the time (36/46 cases). Median colonoscopy duration was 46 minutes, although there was a trend toward shorter procedures over time. This is the first clinical evaluation of the third generation of an intraprocedural cleansing device. We found the device efficacious and easy to use with low procedure failure rates, but it does come with a learning curve. We suspect that adoption of this device mutually will benefit patients and health systems with the potential to improve resource utilization.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials