ArticleQuantitative imaging in medicine and surgery2024
Assessment of the sacroiliac joint in patients with axial spondyloarthritis via three-dimensional ultrashort echo time magnetic resonance imaging.
Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Current State-of-the-Art 3D MRI Sequences for Assessing Bone Morphology with Emphasis on Cranial and Spinal Imaging: A Narrative Review.RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2026Review
- Recent advances and insights into imaging of axial spondyloarthritis.Skeletal radiology · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Bone erosion in the sacroiliac joint (SIJ) is highly specific for the diagnosis of axial spondyloarthritis (axSpA) and may indicate early disease progression. The 3D ultrashort echo time (3D-UTE) technique excels in providing clear contrast between the articular cartilage and the bone cortex interface. Additionally, it is emerging as a promising quantitative tool for detecting early cartilage changes. Therefore, this study aimed to evaluate the diagnostic performance of 3D-UTE sequences in identifying bone erosion in the SIJ of patients with axSpA and to clarify the potential of cartilage T2* values as a quantitative biomarker for axSpA. Methods: This prospective study employed convenience and consecutive sampling methods to recruit patients diagnosed with axSpA in Peking University Third Hospital who met the Assessment of Spondyloarthritis International Society (ASAS) criteria and also an equal number of healthy volunteers. After providing informed consent, all participants underwent 3D-UTE sequences and conventional T2* mapping of the SIJs. Two radiologists separately interpreted the bone erosion of each SIJ on 3D-UTE sequences. Erosion detection of SIJs via computed tomography (CT) served as the standard of reference. The T2* values of the cartilage were measured and compared, and the diagnostic efficacy of the T2* value for axSpA diagnosis was evaluated. Results: A total of 32 patients and 32 healthy volunteers were included. The 3D-UTE sequence, as separately assessed by two reviewers in terms of its ability to detect erosions, exhibited a notable level of accuracy. For the two reviewers, the respective diagnostic sensitivities were 94.7% and 92.9%, the specificities were 97.4% and 96.5%, positive predictive values were 96.7% and 95.4%, the negative predictive values were 95.9% and 94.5%, the accuracies were 96.2% and 94.9%, and the areas under the curve (AUCs) were 96.1% and 94.7%. For the detection of erosions, the interreader κ value was 0.949. The T2* values of the SIJ cartilage were significantly higher in patients with axSpA than in healthy volunteers. The intraobserver intraclass correlation coefficients (ICCs) for T2* measurements ranged between 80.5% and 82.2%. Meanwhile, the interobserver ICCs for UTE-T2* and gradient echo T2* measurements were 81.5% and 80.8%, respectively. The AUCs of the UTE-T2* values for discriminating patients with axSpA from the healthy volunteers of the two readers were 73.3% and 71.6%, respectively. Conclusions: 3D-UTE sequences can be used as a reliable morphological imaging technique for detecting bone erosion in the SIJ. Additionally, UTE-T2* values of the cartilage may offer a quantitative method for identifying patients with axSpA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.