Evidence map›Paper›PMID 38845611›Full record

ArticleOrthopaedic journal of sports medicine2024

Optimizing Socket-Tunnel Position for Meniscal Allograft Transplantation Combined With ACL Reconstruction: A 3D Model Analysis.

Steven DeFroda, João Bourbon de Albuquerque, Will Bezold, Cristi R Cook, Clayton W Nuelle, James P Stannard, James L Cook

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Steven DeFrodaDepartment of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, USA.
João Bourbon de AlbuquerqueDepartment of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, USA.
Will BezoldDepartment of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, USA.
Cristi R CookDepartment of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, USA.
Clayton W NuelleDepartment of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, USA.
James P StannardDepartment of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, USA.
James L CookDepartment of Orthopaedic Surgery, University of Missouri, Columbia, Missouri, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Socket-tunnel overlap during meniscal allograft transplantation (MAT) combined with anterior cruciate ligament reconstruction (ACLR) may compromise graft integrity and lead to impaired fixation and treatment failure. Purpose/Hypothesis: The purpose of this study was to determine optimal socket-tunnel drilling parameters for medial and lateral MAT with concurrent ACLR using artificial tibias and computed tomography (CT) scans for 3-dimensional (3D) modeling. It was hypothesized that clinically relevant socket tunnels could be created to allow for concurrent medial or lateral MAT and ACLR without significant risk for overlap at varying tunnel guide angles. Study Design: Descriptive laboratory study. Methods: A total of 27 artificial right tibias (3 per subgroup) were allocated to 9 experimental groups based on the inclination of the socket tunnels (55°, 60°, and 65°) created for simulating medial and lateral MAT and ACLR. Five standardized socket tunnels were created for each tibia using arthroscopic guides: one for the ACL tibial insertion and one for each meniscus root insertion. CT scans were performed for all specimens and sequentially processed using computer software to produce 3D models for quantitative assessment of socket-tunnel overlap risk. Statistical analysis was performed with Kruskal-Wallis and Mann-Whitney Results: No subgroup consistently presented significantly safer distances than other subgroups for all distances measured. Three cases (11%) and 24 cases (~90%) of tunnel overlap occurred between the ACL tunnel and tunnels for medial and lateral MAT, respectively. Most socket-tunnel overlap (25 of 27; 92.6%) occurred between sockets at depths ranging between 6.3 and 10 mm from the articular surface. For ACLR and posterior root of the lateral meniscus setting, the guide set at 65° increased socket-tunnel distances. Conclusion: When combined ACLR and MAT using socket tunnels for graft fixation is performed, the highest risk for tibial socket-tunnel overlap involves the ACLR tibial socket and the lateral meniscus anterior root socket at a depth of 6 to 10 mm from the tibial articular surface. Clinical Relevance: Setting tibial guides at 65° to the tibial articular surface with the tunnel entry point anteromedial and socket aperture location within the designated anatomic "footprint" will minimize the risk for socket-tunnel overlap.

Indexed as

3D modelinganterior cruciate ligament reconstructionarthroscopykneemeniscal allograft transplantationtunnel convergence

Identifiers

PMID38845611
PMCPMC11155341

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.