Evidence map›Paper›PMID 38844372›Full record

ArticleAJNR. American journal of neuroradiology2024

Cyclic Aspiration in Mechanical Thrombectomy: Influencing Factors and Experimental Validation.

Magda Jablonska, Jiahui Li, Riccardo Tiberi, Esref Alperen Bayraktar, Cem Bilgin, Alejandro Tomasello, Marc Ribo

Registry-linked trialAbstract readValidation Study
In one paragraph

Article in AJNR. American journal of neuroradiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07231380 (Plunger Stroke Trial), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07231380 narecruitingnot on this mapstarted 2026, after this paper: background citation

Plunger Stroke Trial: A Comparison of Cyclic Manual Direct Aspiration Thrombectomy (Plunger Technique) vs. Static Manual Direct Aspiration Thrombectomy for Treatment of Acute Large Vessel Occlusion Stroke With the Raptor Aspiration Catheter

TypeinterventionalSponsorVanderbilt University Medical CenterRan2026 to 2027Enrolled500ConditionsAcute Ischemic Stroke Patients, Large Vessel OcclusionArmsPlunger Technique, Static Manual Aspiration Thrombectomy
3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Magda JablonskaFrom the 2nd Department of Radiology (M.J., Medical University of Gdansk, Gdansk, Poland.ORCID 0000-0002-6108-7977
Jiahui LiStroke Research (J.L., R.T., A.T., M.R.), Vall d'Hebron Research Institute, Barcelona, Spain.ORCID 0000-0003-4278-8222
Riccardo TiberiStroke Research (J.L., R.T., A.T., M.R.), Vall d'Hebron Research Institute, Barcelona, Spain.ORCID 0000-0002-1296-3731
Esref Alperen BayraktarDepartment of Radiology (J.L., E.A.B., C.B.), Mayo Clinic, Rochester, Minnesota.
Cem BilginDepartment of Radiology (J.L., E.A.B., C.B.), Mayo Clinic, Rochester, Minnesota.ORCID 0000-0003-1832-1278
Alejandro TomaselloStroke Research (J.L., R.T., A.T., M.R.), Vall d'Hebron Research Institute, Barcelona, Spain.ORCID 0000-0002-6736-1535
Marc RiboStroke Unit (M.J., M.R.), Vall d'Hebron Research Institute, Barcelona, Spain marcriboj@hotmail.com.ORCID 0000-0001-9242-043X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeMechanical thrombectomy is a fundamental intervention for acute ischemic stroke treatment. While conventional techniques are effective, cyclic aspiration (CyA) shows potential for better recanalization rates. We aim to investigate factors affecting CyA and compare them with static aspiration (StA). MATERIALS AND

methodsStA setup consisted of an aspiration pump connected to pressure transducer. CyA was tested with 5 subsequent iterations: single solenoid valve with air plus saline (i1) or saline alone (i2) as aspiration medium; 2 solenoid valves with air plus saline (i3) as aspiration medium; complete air removal and saline feeding (i4); and pressurized saline feeding (i5). To assess the efficacy of clot ingestion, the pressure transducer was replaced with a distal aspiration catheter. Moderately stiff clot analogs (15 mm) were used to investigate the ingestion quantified as clot relative weight loss. Additionally, the aspiration flow rate was assessed for each setup.

resultsWith CyA i1, the amplitude of the achieved negative pressure waves declined with increasing frequencies but progressively increased with each subsequent iteration, achieving a maximum amplitude of 81 kPa for i5 at 1 Hz. Relative clot weight loss was significantly higher with i5 at 5 Hz than with StA (100% versus 37.8%;

conclusionsCyA with the appropriate setup may represent an encouraging innovation in mechanical thrombectomy, offering a promising pathway for improving efficacy in clot ingestion and recanalization. The observed benefits warrant confirmation in a clinical setting.

Indexed as

ThrombectomyEquipment DesignHumansIschemic StrokeMechanical ThrombolysisSuction

Identifiers

PMID38844372
PMCPMC11543071

What OpenQuestion holds

Textmetadata
Read underepoch 390