Evidence map›Paper›PMID 38843166›Full record

ArticlePloS one2024

A comparative study of 3D measuring methods for monitoring breast volume changes.

Benthe A M Dijkman, Niels P T J Liberton, Sjoerd Te Slaa, Jan Maerten Smit, Chantal M Wiepjes, Koen M A Dreijerink, Martin den Heijer, Rudolf M Verdaasdonk, Christel J M de Blok

Abstract readComparative Study
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Benthe A M DijkmanCenter of Expertise on Gender Dysphoria, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
Niels P T J LibertonDepartment of Medical Technology, 3D Innovation Lab, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
Sjoerd Te SlaaDepartment of Medical Technology, 3D Innovation Lab, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
Jan Maerten SmitCenter of Expertise on Gender Dysphoria, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
Chantal M WiepjesCenter of Expertise on Gender Dysphoria, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
Koen M A DreijerinkCenter of Expertise on Gender Dysphoria, Amsterdam UMC, VU University, Amsterdam, the Netherlands.ORCID 0000-0002-3140-3502
Martin den HeijerCenter of Expertise on Gender Dysphoria, Amsterdam UMC, VU University, Amsterdam, the Netherlands.
Rudolf M VerdaasdonkFaculty of Science and Technology, Health Technology Implementation, University of Twente, Enschede, the Netherlands.
Christel J M de BlokCenter of Expertise on Gender Dysphoria, Amsterdam UMC, VU University, Amsterdam, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Three-dimensional (3D) imaging techniques are promising new tools for measuring breast volume, for example in gender-affirming therapy. Transgender individuals can be treated with gender-affirming hormone therapy (GAHT). A robust method for monitoring breast volume changes is critical to be able to study the effects of feminizing GAHT. The primary aim of this study was to compare the accuracy of three 3D devices (Vectra XT, Artec LEO and iPhone XR) for measuring modest breast volume differences using a mannequin. The secondary aim of this study was to evaluate these methods in several performance domains. We used reference prostheses of increasing volumes and compared the volumes using GOM-inspect software. For Vectra XT 3D images, manufacturer-provided software was used to calculate volumes as well. The scanning methods were ranked based on their performance in a total of five categories: volume estimations, costs, user-friendliness, test subject-friendliness and technical aspects. The 3D models analyzed with GOM-inspect showed relative mean estimate differences from the actual volumes of 9.1% for the Vectra XT, 7.3% for the Artec LEO and 14% for the iPhone XR. For the Vectra XT models analyzed with the built-in software this was 6.2%. Root mean squared errors (RMSE) calculated based on the GOM-inspect volume analyses showed mean RMSEs of 2.27, 2.54 and 8.93 for the Vectra XT, Artec LEO and iPhone XR, respectively. The Vectra software had a mean RMSE of 3.00. In the combined performance ranking, the Vectra XT had the most favorable ranking, followed by the Artec LEO and the iPhone XR. The Vectra XT and Artec LEO are the preferred scanners to monitor breast development due to the combination of higher accuracy and overall performance. The current study shows that 3D techniques can be used to adequately measure modest breast volume differences and therefore will be useful to study for example breast changes in transgender individuals using feminizing GAHT. These observations may also be relevant in other fields of 3D imaging research.

Indexed as

BreastImaging, Three-DimensionalFemaleHumansMaleManikinsOrgan SizeSoftwareTransgender Persons