Evidence map›Paper›PMID 38841515›Full record

ArticleHeliyon2024

Optimal location of PMUs for full observability of power system using coronavirus herd immunity optimizer.

Mohammed A Alghassab, Ahmed Y Hatata, Ahmed H Sokrana, Magdi M El-Saadawi

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mohammed A AlghassabDepartment of Electrical Engineering, College of Engineering, Shaqra University, Al-Dawadmi, Riyadh, 11911, Saudi Arabia.
Ahmed Y HatataDepartment of Electrical Engineering, College of Engineering, Shaqra University, Al-Dawadmi, Riyadh, 11911, Saudi Arabia.
Ahmed H SokranaEgyptian Electricity Transmission Company "EETC", Delta Zone, Protection Sector, Egypt.
Magdi M El-SaadawiDept. of Electrical Engineering, Faculty of Engineering, Mansoura University, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Phasor measurement units (PMU) are currently considered as an essential step toward the future smart grid due to their capability in increasing the power system's situation awareness. Due to their high costs and limited resources, optimal placement of PMUs (OPP) is an important challenge to compute the minimum number of PMUs and their optimal distribution in the power systems for achieving full monitoring. The coronavirus herd immunity optimizer (CHIO) is a novel optimization algorithm that emulates the flock immunity strategies for the elimination of the coronavirus pandemic. In this research, the CHIO is adapted for the OPP problem for full fault observability. The proposed algorithm is implemented on power systems considering the zero injection bus impacts. A program is created in MATLAB® environment to implement the proposed algorithm. The algorithm is applied to different test systems including; IEEE 9-bus, 14-bus, 30-bus, 118-bus, 300-bus, New England 39-bus and Polish 2383-bus. The proposed CHIO-based OPP is compared to some exact and metaheuristic-based OPP techniques. Compared to these techniques, the promising results have proved the effectiveness and robustness of the proposed CHIO to solve the OPP problem for full fault observability.

Indexed as

Coronavirus herd immunity optimizerFault locationFault observabilityPMUWide-area monitoringZero injection buses

Identifiers

PMID38841515
PMCPMC11152686

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.