Evidence map›Paper›PMID 38840962›Full record

ArticleThe Journal of the Canadian Chiropractic Association2024

Intra-observer reliability study of lumbar segmental measurements utilizing ultrasonography.

Ralph Kruse, Maruti Ram Gudavalli, Bret White, Geracimo Bracho, Stacey Rider

Abstract read
In one paragraph

Article in The Journal of the Canadian Chiropractic Association, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ralph KruseKeiser University College of Chiropractic Medicine West Palm Beach, FL.
Maruti Ram GudavalliKeiser University College of Chiropractic Medicine West Palm Beach, FL.
Bret WhiteBruce W. Carter VA Medical Center, Miami, FL.
Geracimo BrachoKeiser University College of Chiropractic Medicine West Palm Beach, FL.
Stacey RiderCity College - HWD, Hollywood, FL.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Spinal Manipulative Therapy (SMT) benefits LBP patients, but its mechanism is not well documented. One hypothesis indicates that SMT restores interspinal movements. Ultrasound measurement (UM) of spinous process separation (SPS) assesses the intersegmental movements. Methods: We used the test-retest reliability of UM between the L3, L4, L5, and S1 spinous processes on fifteen asymptomatic volunteers while lying prone on a chiropractic table. The participants then walked around for over 5 minutes, and ultrasound images were reperformed prone. UM identified the tips of the spinous processes and distances between L3-L4, L4-L5, and L5-S1. Reliability was assessed using intra-class correlation coefficient (ICC). Results: ICC values of SPS measurements were 0.982 for L3-L4, 0.992 for L4-L5, and 0.997 for L5-S1. Rootmean square difference between the two measures were 0.35mm for L5-S1, 0.36mm for L4-L5, and 0.57mm for L3-L4. Conclusions: This study found UM to be reliable in measuring interspinous distance.

Indexed as

chiropracticdiagnostic ultrasoundintersegmental motionlow back painreliabilityspinal manipulation

Identifiers

PMID38840962
PMCPMC11149686

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.