Evidence map›Paper›PMID 38839530›Full record

ArticleInternational dental journal2024

Effects of Oral Appliances for Obstructive Sleep Apnoea in Reduced Periodontium: A Finite Element Analysis.

Manila Caragiuli, Mara Candelari, Francesca Zalunardo, Giovanni Bruno, Alberto De Stefani, Agnese Brunzini, Marco Mandolini

Abstract read
In one paragraph

Article in International dental journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Sleep and periodontal health.Periodontology 2000 · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Manila CaragiuliDepartment of Industrial Engineering and Mathematical Sciences, Università Politecnica delle Marche, Ancona, Italy. Electronic address: m.caragiuli@univpm.it.
Mara CandelariDepartment of Industrial Engineering and Mathematical Sciences, Università Politecnica delle Marche, Ancona, Italy.
Francesca ZalunardoDepartment of Neuroscience, Dental Clinic, Section of Dentistry, University of Padua, Padua, Italy.
Giovanni BrunoDepartment of Neuroscience, Dental Clinic, Section of Dentistry, University of Padua, Padua, Italy; Department of Industrial Engineering, University Tor Vergata, Rome, Italy.
Alberto De StefaniDepartment of Neuroscience, Dental Clinic, Section of Dentistry, University of Padua, Padua, Italy; Department of Pharmacological Sciences, University of Padua, Padua, Italy.
Agnese BrunziniDepartment of Industrial Engineering and Mathematical Sciences, Università Politecnica delle Marche, Ancona, Italy.
Marco MandoliniDepartment of Industrial Engineering and Mathematical Sciences, Università Politecnica delle Marche, Ancona, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectiveIn the literature, no studies correlate the effects of mandibular advancement devices (MADs) with different titration systems to periodontitis. Through a finite element analysis (FEA), this study investigates the effects generated on periodontal ligaments (PDLs) and teeth by four commercial MADs in periodontal health and with 15% bone resorption.

methodsFour MADs (Somnodent Flex™, Somnodent Avant™, Orthoapnea™, and Herbst™) were digitalised starting from the impressions of a patient's dental arches. A force of 11.18 N, representing an advancement of 9.5 mm, was applied, and a FEA was subsequently performed. After measuring the stresses and displacements on the PDLs and teeth in healthy periodontal conditions, the vertical dimension of the alveolar bone was reduced by 15%, and measurements were repeated.

resultsIn terms of PDL stress, Herbst™ is the device which guarantees a more uniform increment in case of the first stage of periodontitis (+7% for mandibular and maxillary PDLs compared to the healthy condition). For Somnodent™ devices, the PDLs stress increment is almost null for mandibular PDLs but much higher than Herbst™ for maxillary PDLs (+17% and +21% for Flex™ and Avant™). Orthoapnea™ determines a PDL stress augmentation between the other devices (+16% and +7%, respectively, for maxillary and mandibular PDLs). Concerning teeth movement, Herbst™ and Orthoapnea™ determine a lower and more uniform displacement than Somnodent devices.

conclusionsThe stress distribution and teeth displacement are strictly related to MAD geometry. Since its minor effects on teeth and PDLs, the Herbst™ could be more appropriate in patients with periodontitis.

Indexed as

Finite Element AnalysisPeriodontal LigamentSleep Apnea, ObstructiveDental Stress AnalysisHumansMandibular AdvancementPeriodontitisPeriodontiumFinite element analysisFinite element methodMandibular advancement deviceObstructive sleep apnoeaPeriodontal diseasePeriodontal stress

Identifiers

PMID38839530
PMCPMC11551564

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.