Evidence map›Paper›PMID 38838332›Full record

ArticleJMIR formative research2024

Performance of a Wearable Ring in Controlled Hypoxia: A Prospective Observational Study.

John J Mastrototaro, Michael Leabman, Joe Shumate, Kim L Tompkins

Registry-linked trialAbstract read
In one paragraph

Article in JMIR formative research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05920278 (Performance of the Movano Health Ring in a Controlled Hypoxia Study), which is not on this map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05920278 completednot on this map

Performance of the Movano Health Ring in a Controlled Hypoxia Study: Prospective Observational Study

TypeobservationalSponsorMovano HealthRan2022 to 2022Enrolled11ConditionsHypoxiaArmsPulse oximeter
3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

John J MastrototaroMovano Inc dba Movano Health, Pleasanton, CA, United States.ORCID https://orcid.org/0009-0005-1579-4098
Michael LeabmanMovano Inc dba Movano Health, Pleasanton, CA, United States.ORCID https://orcid.org/0009-0002-2530-0862
Joe ShumateMovano Inc dba Movano Health, Pleasanton, CA, United States.ORCID https://orcid.org/0009-0003-7146-8989
Kim L TompkinsMovano Inc dba Movano Health, Pleasanton, CA, United States.ORCID https://orcid.org/0009-0008-0357-2019

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOver recent years, technological advances in wearables have allowed for continuous home monitoring of heart rate and oxygen saturation. These devices have primarily been used for sports and general wellness and may not be suitable for medical decision-making, especially in saturations below 90% and in patients with dark skin color. Wearable clinical-grade saturation of peripheral oxygen (SpO

objectiveThis study aimed to determine the SpO

methodsWe performed a single-center, blinded hypoxia study of the test device in 11 healthy volunteers at the Hypoxia Research Laboratory, University of California at San Francisco, under the direction of Philip Bickler, MD, PhD, and John Feiner, MD. Each volunteer was connected to a breathing apparatus for the administration of a hypoxic gas mixture. To facilitate frequent blood gas sampling, a radial arterial cannula was placed on either wrist of each participant. One test device was placed on the index finger and another test device was placed on the fingertip. SaO

resultsFor the 11 participants included in the analysis, there were 236, 258, and 313 SaO

conclusionsThe wearable ring meets an acceptable standard of accuracy for clinical-grade SpO

trial registrationClinicalTrials.gov NCT05920278; https://clinicaltrials.gov/study/NCT05920278.

Indexed as

accuracyclinical trialdigital healthhypoxemiahypoxiaISO 80601-2-61pulse oximeterpulse oximetryracial biassmart ringSpO2wearable

Identifiers

PMID38838332
PMCPMC11187508

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.