Evidence map›Paper›PMID 38838164›Full record

ArticleJournal of synchrotron radiation2024

Hard X-ray operation of X-ray gas monitors at the European XFEL.

Theophilos Maltezopoulos, Frank Brinker, Florian Dietrich, Wolfgang Freund, Jan Grünert, Ulf Fini Jastrow, Naresh Kujala, Joakim Laksman, Jia Liu, Kai Tiedtke and 1 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Theophilos MaltezopoulosEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Frank BrinkerDeutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
Florian DietrichEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Wolfgang FreundEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Jan GrünertEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Ulf Fini JastrowDeutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
Naresh KujalaEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Joakim LaksmanEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-5507-8652
Jia LiuEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0003-0073-4998
Kai TiedtkeDeutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.ORCID 0000-0002-6535-1050
Thomas TschentscherEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-2009-6869

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

X-ray gas monitors (XGMs) are operated at the European XFEL for non-invasive single-shot pulse energy measurements and average beam-position monitoring. The underlying measurement principle is the photo-ionization of rare gas atoms at low gas pressures and the detection of the photo-ions and photo-electrons created. These are essential for tuning and sustaining self-amplified spontaneous emission (SASE) operation, machine radiation safety, and sorting single-shot experimental data according to pulse energy. In this paper, the first results from XGM operation at photon energies up to 30 keV are presented, which are far beyond the original specification of this device. Here, the Huge Aperture MultiPlier (HAMP) is used for single-shot pulse energy measurements since the standard X-ray gas monitor detectors (XGMDs) do not provide a sufficient signal-to-noise ratio, even at the highest operating gas pressures. A single-shot correlation coefficient of 0.98 is measured between consecutive XGMs operated with HAMP, which is as good as measuring with the standard XGMD detectors. An intra-train non-linearity of the HAMP signal is discovered, and operation parameters to mitigate this effect are studied. The upper repetition rate limit of HAMP operation at 2.25 MHz is also determined. Finally, the possibilities and limits for future XGM operation at photon energies up to 50 keV are discussed.

Indexed as

free-electron lasershard X-raysHuge Aperture MultiPlierphoton diagnosticsX-ray gas monitors

Identifiers

PMID38838164
PMCPMC11226157

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.