Evidence map›Paper›PMID 38836910›Full record

ArticleJournal of gastroenterology2024

Red dichromatic imaging and linked color imaging as reliable image-enhanced endoscopic procedures for detecting the distal end of the palisade vessels in the columnar metaplastic mucosa of the gastroesophageal junction zone.

Satoshi Ono, Keiko Yamamoto, Fumiaki Ishibashi, Ai Fujimoto, Yuji Urabe, Tsutomu Takeda, Hideki Ishikawa, Mitsuhiro Fujishiro, Takuji Gotoda, Michio Kaminishi and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of gastroenterology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Upper Gastrointestinal Endoscopy in Elderly Patients: An Individualized Decision-Making Approach for Screening and Surveillance.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2026
    Review
  2. Observational
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Satoshi OnoDepartment of Gastroenterology and Gastrointestinal Endoscopy, Tokyo Metropolitan Institute for Geriatrics and Gerontology, Tokyo, Japan.
Keiko YamamotoDivision of Endoscopy, Hokkaido University Hospital, Kita 14 Nishi 5, Kita-Ku, Sapporo, 060-8648, Japan. keiko_sannai@yahoo.co.jp.ORCID 0000-0003-2343-2984
Fumiaki IshibashiDepartment of Gastroenterology, International University of Health and Welfare Ichikawa Hospital, Chiba, Japan.
Ai FujimotoDepartment of Gastroenterology and Hepatology, Division of Internal Medicine, Toho University Omori Medical Center, Tokyo, Japan.
Yuji UrabeDepartment of Gastroenterology, Hiroshima University Hospital, Hiroshima, Japan.
Tsutomu TakedaDepartment of Gastroenterology, Juntendo University School of Medicine, Tokyo, Japan.
Hideki IshikawaDepartment of Molecular-Targeting Prevention, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Mitsuhiro FujishiroDepartment of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Takuji GotodaDepartment of Gastroenterology, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Tokyo, Japan.
Michio KaminishiDepartment of Gastroenterology, Tamaryokuseikai Foundation, Tokyo, Japan.
Kentaro SuganoDepartment of Internal Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke, Tochigi, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThere is a consensus that identifying the distal end of the palisade vessels (DEPV) is important for diagnosing gastroesophageal junction (GEJ). However, optimum observation methods have not been established. This study investigated the use of effective image-enhanced endoscopy (IEE) for DEPV detection.

methodsOne hundred endoscopic images in 20 cases of columnar metaplastic mucosa of the GEJ recorded with white-light imaging (Olympus-WLI and Fujifilm-WLI) and IEEs (narrow-band imaging; RDI1/2/3, red dichromatic imaging; texture and color enhancement imaging 1/2; blue-laser imaging; and LCI, linked color imaging) from two manufacturers were extracted and evaluated by 10 evaluators. Up to 24 radial straight lines from the center of the lumen were placed on the image, and the evaluators placed markings according to confidence level (high, low, and not detectable) at the DEPV locations. The detectability and reproducibility at the rate of the confidence level and coefficient of variance of markings among the evaluator were analyzed.

resultsIn total, 15,180 markings were obtained. In terms of detectability, RDI1 (49.4%), RDI2 (53.0%), RDI3 (54.1%), TXI2 (49.7%), and LCI (34.6%) had a significantly higher rate of high confidence among the IEEs in each manufacturer. By contrast, Olympus-WLI (40.6%), Fujifilm-WLI (17.6%), narrow-band imaging (15.9%), and blue laser imaging (9.8%) presented with a significantly lower rates of high confidence. Regarding reproducibility, RDI3 and LCI had the lowest coefficient of variance for each manufacturer.

conclusionsRDI and LCI could be reliable modalities for detecting DEPVs in the columnar metaplastic mucosa of the GEJ zone.

Indexed as

Esophagogastric JunctionImage EnhancementColorEsophageal MucosaFemaleGastric MucosaHumansMetaplasiaNarrow Band ImagingReproducibility of ResultsEndoscopyGastroesophageal junctionMucous membrane

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.