ArticleFrontiers in neurology2024
Single-channel seizure detection with clinical confirmation of seizure locations using CHB-MIT dataset.
Article in Frontiers in neurology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Patient-independent automated pediatric seizure monitoring based on expert-labeled electrographic ictal data as core reference knowledge.Clinical and experimental pediatrics · 2026Article
- CosFNet: A Lightweight Epileptic EEG Detection Model Based on Cosine Convolution and FNet.Bioengineering (Basel, Switzerland) · 2026Article
- Single-channel EEG-based seizure prediction using deep learning.Scientific reports · 2026Article
- Near-Real-Time Epileptic Seizure Detection with Reduced EEG Electrodes: A BiLSTM-Wavelet Approach on the EPILEPSIAE Dataset.Brain sciences · 2026Article
- Efficient and Accurate Epilepsy Seizure Prediction and Detection Based on Multi-Teacher Knowledge Distillation RGF-Model.Brain sciences · 2026Article
- Research on epilepsy detection and recognition based on the combination of time frequency transform and deep learning model.PloS one · 2026Article
- Real-Time Multi-Channel Epileptic Seizure Detection Exploiting an Ultra-Low-Complexity Algorithm-Hardware Co-Design Approach.Sensors (Basel, Switzerland) · 2025Article
- A Novel Co-Designed Multi-Domain Entropy and Its Dynamic Synapse Classification Approach for EEG Seizure Detection.Entropy (Basel, Switzerland) · 2025Article
- Epileptic Seizure Detection Using Machine Learning: A Systematic Review and Meta-Analysis.Brain sciences · 2025Review
- Personalizing Seizure Detection for Individual Patients by Optimal Selection of EEG Signals.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Long-term electroencephalography (EEG) monitoring is advised to patients with refractory epilepsy who have a failure of anti-seizure medication and therapy. However, its real-life application is limited mainly due to the use of multiple EEG channels. We proposed a patient-specific deep learning-based single-channel seizure detection approach using the long-term scalp EEG recordings of the Children's Hospital Boston-Massachusetts Institute of Technology (CHB-MIT) dataset, in conjunction with neurologists' confirmation of spatial seizure characteristics of individual patients. Methods: We constructed 18-, 4-, and single-channel seizure detectors for 13 patients. Neurologists selected a specific channel among four channels, two close to the behind-the-ear and two at the forehead for each patient, after reviewing the patient's distinctive seizure locations with seizure re-annotation. Results: Our multi- and single-channel detectors achieved an average sensitivity of 97.05-100%, false alarm rate of 0.22-0.40/h, and latency of 2.1-3.4 s for identification of seizures in continuous EEG recordings. The results demonstrated that seizure detection performance of our single-channel approach was comparable to that of our multi-channel ones. Discussion: We suggest that our single-channel approach in conjunction with clinical designation of the most prominent seizure locations has a high potential for wearable seizure detection on long-term EEG recordings for patients with refractory epilepsy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.